Chemistry |
C18 |
|
Separation Mode |
Reversed Phase |
|
Particle Substrate |
Silica |
|
pH Range Min |
3 pH |
|
pH Range Max |
7 pH |
|
Maximum Pressure |
6000 psi (415 Bar) |
|
Endcapped |
Yes |
|
Bonding Technology |
dC18 |
|
Silanol Activity |
Medium |
|
Particle Shape |
Spherical |
|
Particle Size |
3 µm |
|
Endfitting Type |
Waters |
|
Pore Size |
100 Å |
|
Format |
Column |
|
Surface Area |
330 |
|
System |
HPLC |
|
USP Classification |
L1 |
|
Inner Diameter |
3 mm |
|
Length |
100 mm |
|
Carbon Load |
12 % |
|
UNSPSC |
41115709 |
|
Brand |
Atlantis |
|
Product Type |
Columns |
|
Units per Package |
1 pk |
Atlantis dC18 Column, 100Å, 3 µm, 3 mm X 100 mm, 1/pk
Atlantis dC18 columns are universal reversed-phase C18 columns made of silica. They are used to retain polar compounds. The di-functionally bound C18 ligands in the Atlantis dC18 columns have been improved for usage with extremely watery mobile phases, including 100 percent water.
The Atlantis dC18 analytical column is a universal C18 column that is compatible with both LC and MS. In contrast to traditional reversed-phase HPLC columns, it has been engineered to achieve an excellent balance of retention for polar and nonpolar chemicals while demonstrating minimal retention of hydrophobic compounds. The Atlantis dC18 Column is compatible with aqueous mobile phases and has improved pH stability. The silica-based, di-functionally bonded C18 material of this equipment makes it an ideal piece of lab equipment for reversed-phase HPLC because of its carefully developed packing material that offers retention and separation of polar, water-soluble chemicals.
The Atlantis dC18 Column combines optimized stationary phase features such as end-capping, silica pore size, ligand type, and bonded phase ligand density to give superior peak form, low pH stability, improved polar compound retention, and hydrophobic collapse resistance (dewetting). The Atlantis dC18 Column, as one of the best reversed-phase HPLC columns, is appropriate for both polar compound separation and typical reversed-phase applications. The di-functional silane bonding chemistry used in the Atlantis dC18 column provides good stability under acidic mobile conditions, as well as a longer column lifetime and low pH stability.
With the right lab equipment, you can boost your productivity. Check out our shop for lab equipment to discover more about variations of the same product, such as the Atlantis dC18 Column, or to locate additional goods that work with it. You may browse our website, refer to our catalog, and ensure your lab needs are covered as needed.
Compatible with the Atlantis dC18 Columns, you might also be interested in Atlantis Silica dC18 VanGuard Cartridge, 100Å, 3 µm, 2.1 mm X 5 mm, 3/pk; Atlantis dC18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. Atlantis dC18 analytical columns containing 3 µm sorbent particles.
How Is The Atlantis dC18 Column Equilibrated
The Atlantis dC18 Column comes packed and shipped with 100% acetonitrile; therefore, it is of utmost importance to ensure the column and solvent are compatible before changing to a new solvent. To equilibrate the Atlantis dC18 Column, you can use 10 column volumes of the mobile phase to be used. Kindly ensure the equipment is handled with care, and don't leave any droplets on the outside of the column.