Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
MS C18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Waters |
Pore Size |
125 Å |
Format |
Column |
Surface Area |
175 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
75 mm |
Carbon Load |
16 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Columns |
Units per Package |
1 pk |
XTerra MS C18 Column, 125Å, 2.5 µm, 4.6 mm X 75 mm, 1/pk
Use the XTerra MS C18 Column to benefit from greater pH stability over a silica-based column. A general-purpose, hybrid-based, reversed-phase C18 column has been constructed for mass spectrometry applications. Sharp peak forms, high sensitivity, and huge peak capacities are all features of the XTerra MS C18 column. This is accomplished by utilizing the XTerra particles' tri-functional bonding chemistry. When compared to traditional silica-based columns, the lab equipment provides one of the longest lives over a broad pH range, as well as maximum throughput, superb resolution, and ultra-low column bleed.
The XTerra MS C18 Column is made with only ultrapure reagents, and the chemical composition and purity of the hybrid particle are strictly controlled. Every stage of the production process is meticulously regulated and carried out within tight tolerances. In addition, each column is individually tested to ensure that you receive only the highest quality lab equipment. Certificates of Batch Analysis and Column Efficiency are also provided with each column to ensure quality.
Waters Hybrid Particle Technology was used to create the packing materials for the XTerra MS C18 column. The particles combine the benefits of both silica and organosiloxane components because they comprise both inorganic (silica) and organic (organosiloxane) components. When compared to silica-based reversed-phase packing materials, this hybrid technology allows the XTerra MS C18 column to provide great separation efficiency and better pH stability.
The XTerra MS C18 column listed here is one of the many variants available. You can shop for lab equipment that is most suitable for your needs by exploring the Waters website.
You may also be interested in the XTerra MS C18 VanGuard Cartridge, 125Å, 2.5 µm, 3.9 mm X 5 mm, 3/pk. By eliminating dangerous compounds and particulate matter from the mobile phase, the VanGuard Cartridge protects your analytical column from harm and extends its lifetime. The lab equipment employs the same packing material as the column, ensuring that you get the best results possible.
What Is The pH Range For The XTerra MS C18 Column?
The XTerra MS C18 Column listed here offers a pH range of 1-12 pH.
What Is The Maximum Pressure Recommended For The XTerra MS C18 Column?
For this particular XTerra MS C18 Column, the maximum recommended pressure is 6000 psi (415 Bar).