SKU: 186000861
XTerra Hybrid Shield RP18 Method Validation Kit, 125Å, 3.5 µm, 4.6 mm X 150 mm, 3/pk

XTerra Hybrid Shield RP18 Method Validation Kit | 186000861


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

This kit consists of three XTerra RP 18 columns packed with three different batches of sorbent.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    125 Å

  • Format

    Method Validation Kit

  • Surface Area

    175

  • System

    HPLC

  • Particle Technology

    Hybrid

  • USP Classification

    L1

  • Inner Diameter

    4.6 mm

  • Length

    150 mm

  • Carbon Load

    15 %

  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Column Kits

  • Units per Package

    3 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XTerra Hybrid Shield RP18 Method Validation Kit, 125Å, 3.5 µm, 4.6 mm X 150 mm, 3/pk

Use the all-purpose, hybrid-based, reversed-phase XTerra Hybrid Shield RP18 Method Validation Kit to give better peak shape performance for highly basic chemicals. This lab equipment contains Waters' unique embedded polar group technology. The first generation XTerra Hybrid Shield RP18 Method Validation Kit offers greater pH stability when compared to a silica-based column.

Surpass the major drawbacks of the silica-based reversed-phase packing materials thanks to the XTerra Hybrid Shield RP18 Method Validation Kit's usage of Waters' proprietary organic/inorganic Hybrid Particle Technology (HPT). At high pH, you can specifically overcome their hydrolytic instability. As a result, the Waters XTerra range of reversed-phase HPLC columns is the first alternative to silica-based column technology that is commercially accessible.

The columns, like all Waters columns, are produced in accordance with ISO 9001 guidelines, guaranteeing that each stage is carried out to the highest standards and tightest tolerances. Additionally, each column is checked individually to determine how well it performs. Each column comes with a certificate of Batch Analysis and Column Efficiency as additional assurance of its superior quality.

Invest in the Waters XTerra Hybrid Shield RP18 Method Validation Kit, which has the mechanical strength, extremely spherical shape, purity, pore dimensions, surface area, ability to customize particle size, pore dimensions, surface area, and surface chemistry of its silica equivalents. This is accomplished by utilizing conventional bonding agents, making the use of XTerra Shield RP18 Column versatility. Additionally, it enables lab equipment to work at its best for highly basic substances while maintaining excellent separation efficiency and increased pH stability. The lab equipment can also function across a wide pH range.

Prevent any unwanted contaminants from entering the mobile phase and interfering with the analysis results using the XTerra Shield RP18 VanGuard Cartridge, 125Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk. This delivers more accurate results while enhancing the lifetime of the column.

What pH Range Works For The XTerra Hybrid Shield RP18 Method Validation Kit?

The XTerra Hybrid Shield RP18 Method Validation Kit listed here is able to function well across the 2-12 pH range.

What Maximum Pressure Is Tolerated By The XTerra Hybrid Shield RP18 Method Validation Kit?

This particular XTerra Hybrid Shield RP18 Method Validation Kit can withstand a maximum of 6,000 psi (415 Bar).