Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
MS C18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
125 Å |
Format |
Method Validation Kit |
Surface Area |
175 |
System |
HPLC |
Particle Technology |
Hybrid |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
250 mm |
Carbon Load |
16 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Column Kits |
Units per Package |
3 pk |
XTerra Hybrid MS C18 Method Validation Kit, 125Å, 5 µm, 4.6 mm X 250 mm, 3/pk
The Waters XTerra MS C18 columns offer precise peaks, good sensitivity, and significant peak capacities and have been intended to be suitable for Mass Spectrometry applications. These chemicals have peak shapes that are often only possible in columns using embedded polar group technology. The tri-functional bonding chemistries of XTerra MS columns present in the XTerra Hybrid MS C18 Method Validation Kit give the highest throughput with exceptional resolution and ultra-low bleed, as well as the longest life over the greatest pH range.
The XTerra columns have become the fastest-selling and most successful lab equipment in the world of chromatography thanks to the widespread adoption by pharmaceutical professionals in drug discovery, method development, isolation, and purification. The underlying physics of hybrid particle technology is the cause. The tough XTerra particle's resistance to DMSO injection is useful to drug discovery experts. The wide pH range of XTerra columns allows method development scientists to work at whatever pH is required for the best selectivity. Because of the large mass loading capacity of XTerra columns, isolation and purification researchers can inject up to 60 times more material per injection.
Waters Hybrid Particle Technology is used to create the packing materials used by the XTerra Hybrid MS C18 Method Validation Kit. The advantages of both organic (organosiloxane) and inorganic (silica) components are combined in XTerra particles. Comparing hybrid technology to reversed-phase packing materials based on silica, the high efficiency of separation and increased pH stability is possible. You can discover the complete range of XTerra lab equipment from our online store to find the one that matches your needs. The online store also enables you to shop for lab equipment directly from us.
Ultrapure reagents are used to create XTerra Columns in order to regulate the chemical make-up and purity of the hybrid particle. Each column is tested separately during each manufacturing phase, which is done within a small range of tolerances. Each column comes with a certificate of batch analysis and column efficiency. You may want to invest in the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.
What Is The pH Range Offered By The XTerra Hybrid MS C18 Method Validation Kit?
The XTerra Hybrid MS C18 Method Validation Kit listed here is able to function well across the 1-12 pH Range.
What Is The Maximum Pressure Recommended For The XTerra Hybrid MS C18 Method Validation Kit?
This particular XTerra Hybrid MS C18 Method Validation Kit has been designed to be able to withstand a maximum of 6000 psi (415 Bar) pressure.