Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
335 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
150 mm |
Carbon Load |
19 % |
UNSPSC |
41115709 |
Brand |
Symmetry |
Product Type |
Columns |
Units per Package |
1 pk |
Symmetry C18 Column, 100Å, 3.5 µm, 3 mm X 150 mm, 1/pk
The Symmetry C18 Column delivers outstanding reproducibility year on year. You would not need to continuously revalidate nor redevelop methods with each batch of columns, thus saving labor costs otherwise incurred using traditional analytical columns that require extensive QC column testing.
The Symmetry C18 Columns are manufactured in the cGMP, ISO9001, and ISO13485 certified facilities where each step of the manufacturing process is closely monitored and required conditions are met, thereby enabling the Symmetry C18 Column to have the tightest specifications in the market to provide reproducible and consistent results each time. This result is achieved by ensuring the Symmetry C18 Columns are produced using only high purity raw materials and column packaging procedures that result in the most reproducible HPLC column.
Another interesting feature of the Symmetry C18 Column is that they contain monofunctionally bonded C18 ligands on high purity base-deactivated silica, which lead to the column giving the highest reproducibility. The Symmetry C18 Column also features the narrowest ligand density specifications, which lead to minimal shifts in resolution and more reproducible batch to batch results. Due to these features, you will be able to maximize the efficiency and precision in your lab. The Symmetry C18 Columns are also shipped with a three-page Certificate of Analysis that covers the column specifications as well as outlines results of twenty-two critical tests that each of the columns has to pass through before being quality assured.
You can increase your productivity with the ideal lab equipment. To learn more about the variations of the same product, such as the Symmetry C18 Column, or to find additional products that work with it, check out our shop for lab equipment; you can browse through our website, refer to our catalog and ensure your lab needs are met as needed.
You may also be interested in Symmetry C18 VanGuard Cartridge, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk, which works very well in conjunction with the Symmetry C18 Columns and enhances the performance and lifetime of the analytical column by protecting it from undesired and harmful contaminants in the mobile phase.
What Is The Recommended pH Range For The Symmetry C18 Column?
The Symmetry C18 Column works well between the operating pH range of 2-8.