SKU: 186000646
XTerra Shield RP18 Sentry Guard Cartridge, 125Å, 3.5 µm, 3.9 mm X 20 mm, 2/pk

XTerra Shield RP18 Sentry Guard Cartridge | 186000646


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Pore Size

    125 Å

  • Format

    Sentry Guard Cartridge

  • Surface Area

    175

  • System

    HPLC

  • USP Classification

    L1

  • Inner Diameter

    3.9 mm

  • Length

    20 mm

  • Carbon Load

    15 %

  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Guards

  • Units per Package

    2 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XTerra Shield RP18 Sentry Guard Cartridge, 125Å, 3.5 µm, 3.9 mm X 20 mm, 2/pk

For reversed-phase liquid chromatography, the Waters XTerra Shield RP18 Sentry Guard Cartridge is intended to be used with XTerra Shield columns. The lab equipment is a single piece that may be fastened directly to the analytical XTerra Column's inlet side. Your XTerra Shield Column is safeguarded against harmful contaminants, whether chemical or particle, owing to the XTerra Shield RP18 Sentry Guard Cartridge, which is simple to install. By removing any chemical and particle contaminants from the mobile phase stream, its use will enhance and improve the analytical performance of the column.

The XTerra Shield RP18 Sentry Guard Cartridge is produced in compliance with the most stringent standards. Each item is additionally evaluated and approved for usage to ensure that the lab equipment will function optimally and improve the selectivity, sensitivity, and speed of your investigation. The XTerra Shield RP18 Sentry Guard Cartridge is made from the same premium components as the XTerra Shield RP18 Column. As a result, the lab equipment is perfectly suited for the XTerra Shield RP18 Column's protection.

The XTerra Shield RP18 Sentry Guard Cartridge is produced in a cGMP, ISO 9001-certified facility utilizing ultra-pure reagents. Additionally, the packing material for the XTerra Shield RP18 Sentry Guard Cartridge is put through chromatographic testing using neutral, acidic, and basic analytes for each batch.

Waters has created the XTerra RP18 columns, which are general-purpose, hybrid-based, reversed-phase C18 columns that make use of Waters' unique integrated polar group technology in order to enhance peak shape performance for highly basic chemicals. Comparing these first-generation columns to a silica-based column, they offer improved pH stability. In order to ensure that the lab equipment lasts you a long time, it is essential to keep it safe from harm. The XTerra Shield RP18 Sentry Guard Cartridge was created with this goal in mind, and it does so with extraordinary effectiveness.

Store your analytes safely using the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.

What Is The pH Range Offered By The XTerra Shield RP18 Sentry Guard Cartridge?

The XTerra Shield RP18 Sentry Guard Cartridge listed here is able to comfortably work across the 2-12 pH range.

What Is The Maximum Pressure That Is Recommended For The XTerra Shield RP18 Sentry Guard Cartridge?

This particular XTerra Shield RP18 Sentry Guard Cartridge has a maximum pressure tolerance of 6,000 psi (415 Bar).