Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP8 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
125 Å |
Format |
Column |
Surface Area |
175 |
System |
HPLC |
USP Classification |
L7 |
Inner Diameter |
4.6 mm |
Length |
50 mm |
Carbon Load |
14 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Columns |
Units per Package |
1 pk |
XTerra Shield RP8 Column, 125Å, 5 µm, 4.6 mm X 50 mm, 1/pk
Utilize the XTerra Shield RP8 Column to get around the severe drawbacks of silica-based reversed-phase packing materials. The lab equipment makes use of the proprietary organic/inorganic hybrid particle technology (HPT) from Waters, which was created expressly to address the hydrolytic instability of conventional silica columns at high pH. The XTerra Shield RP8 Column is the first commercially viable substitute for silica-based column technology as a result.
High-purity methyl hybrid material, which is made using a process similar to that of high-purity silica, is used in the XTerra Shield RP8 Column's construction. The XTerra packing is created from the combined condensation of two high-purity monomers as opposed to one, which is a significant distinction. Tetraethoxysilane (TEOS) and methyltriethoxysilane are used in the hybrid particle synthesis process to create the XTerra column (MTEOS). Additionally, the columns are produced in accordance with ISO 9001 guidelines, guaranteeing that every stage is carried out to the highest standards and tightest tolerances. In addition to this, each lab equipment is evaluated independently to ensure that it performs as promised. Along with each column, certificates of batch analysis and column efficiency are also given.
Visit our website to learn more about the XTerra brand and the different columns and chemistries that have been created to cater to the various needs that arise during analysis. Additionally, you may shop for lab equipment there and access a wealth of literature that describes the technology behind the various pieces of lab equipment.
Benefit from the special advantages of the XTerra Shield RP8 Column by including it in your collection of lab equipment. The column has several important benefits, including mechanical strength, a highly spherical shape, purity, pore size, surface area, and the capacity to customize particle size. Utilizing conventional bonding agents enables this. Additionally, it makes the XTerra Shield RP8 Column versatile and able to retain excellent separation efficiency while providing optimal shape performance for extremely basic chemicals. Further, the analytical column offers increased pH stability and works with a wide pH range.
Protect your column from harm by using the XTerra Shield RP8 VanGuard Cartridge, 125Å, 5 µm, 3.9 mm X 5 mm, 3/pk.
What pH Range Does The XTerra Shield RP8 Column Offer?
This particular XTerra Shield RP8 Column is able to work well within the 2-12 pH range.