SKU: 186000482
XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 50 mm, 1/pk

XTerra MS C18 Column | 186000482


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    MS C18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    125 Å

  • Format

    Column

  • Surface Area

    175

  • System

    HPLC

  • USP Classification

    L1

  • Inner Diameter

    4.6 mm

  • Length

    50 mm

  • Carbon Load

    16 %

  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 50 mm, 1/pk

Include the XTerra MS C18 Column in your collection of lab equipment. The analytical column is a general-purpose, hybrid-based, reversed-phase C18 column that was made to work with a variety of mass spectrometry applications. When compared to a silica-based column, the first-generation XTerra MS C18 Column can offer improved pH stability.

The XTerra MS C18 Column is designed to be uniquely suited for Mass Spectrometry applications and delivers sharp peak forms, exceptional sensitivity, and big peak capacities. When compared to standard silica-based columns, the lab equipment uses the tri-functional bonding chemistry of the XTerra particles to give one of the longest lives over the greatest pH range. This is in addition to offering the highest throughput, exceptional resolution, and extremely little column leakage.

The XTerra MS C18 Column is created with ultrapure reagents, much like all other lab equipment sold as being made by Waters, guaranteeing the control of the chemical composition and purity of the hybrid particle. Every stage of the production process is meticulously monitored, controlled, and done within very strict tolerances. To ensure that you only receive the highest caliber lab equipment, each column is additionally put through an individual test. Certificates of Batch Analysis and Column Efficiency are provided with each column to ensure that you have high-quality lab equipment.

Waters Hybrid Particle Technology is used to create the XTerra packaging materials. These particles combine the benefits of both organic and inorganic materials by combining both inorganic (silica) and organic (organosiloxane) components. When compared to reversed-phase packing materials made of silica, the XTerra MS C18 Column delivers great separation efficiency and improved pH stability owing to the employment of this hybrid technology.

You may also want to invest in the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. These vials are made to meet the requirements of LC/GC certification and to take into account all aspects of use, including volatility, tray design, and needle design. An HPLC test is performed on every vial to check for traces of compounds introduced during processing and manufacture. The improved resealing properties of the PTFE/Silicone septum will help with repeated injections and sample storage.

What Are The Minimum And Maximum pH Limits Of The XTerra MS C18 Column?

The Waters XTerra MS C18 Column listed here is able to function well across the 1-12 pH range.

Is There A Recommended Maximum Pressure For The XTerra MS C18 Column?

This particular XTerra MS C18 Column has been designed to easily withstand a maximum of 6,000 psi (415 Bar) pressure.