Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP8 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
125 Å |
Format |
Column |
Surface Area |
175 |
System |
HPLC |
USP Classification |
L7 |
Inner Diameter |
3 mm |
Length |
150 mm |
Carbon Load |
14 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Columns |
Units per Package |
1 pk |
XTerra Shield RP8 Column, 125Å, 5 µm, 3 mm X 150 mm, 1/pk
By including the XTerra Shield RP8 Column in your collection of lab equipment, you can easily take advantage of its special qualities. The features of the column include mechanical strength, very spherical shape, purity, pore diameters, surface area, ability to alter particle size, and surface chemistry. This is made possible by the employment of conventional bonding agents. In addition to this, it makes the XTerra Shield RP8 Column adaptable, enabling it to maintain good separation efficiency while achieving ideal shape performance for extremely basic compounds. The analytical column can operate over a wide pH range and has improved pH stability.
Overcome the significant limitations of reversed-phase packing materials based on silica by using the XTerra Shield RP8 Column. In order to overcome the hydrolytic instability of traditional silica columns at high pH, Waters developed the proprietary organic/inorganic Hybrid Particle Technology (HPT), which is used in the lab equipment. The XTerra Shield RP8 Column is the first commercially available silica-free column as a result.
High-purity methyl hybrid material, which is created in the same manner as high-purity silica, is used to make the XTerra Shield RP8 Column. On the other hand, the XTerra material is created by the condensation of two high-purity monomers as opposed to one. The XTerra column is made using the Hybrid Particle Synthesis of Tetraethoxysilane (TEOS) and Methyltriethoxysilane (MTOS) (MTEOS). The columns are also produced in accordance with ISO 9001 standards, guaranteeing that every procedure is completed to the highest standards and with the tightest tolerances possible. Additionally, each column is independently assessed to make sure it functions as planned. A certificate of batch analysis and column efficiency is provided with each column.
Visit our website to find out more about the XTerra brand and the many columns and chemistries that have been specially designed to meet the requirements of your lab. There is also a substantial body of literature that covers the technology used in various types of lab equipment as well as the possibility of purchasing lab equipment.
We recommend that you store your analytes in the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.
What Is The pH Range Offered By The XTerra Shield RP8 Column?
The Waters XTerra Shield RP8 Column listed here is able to work well across the broad 2-12 pH range.
What Is The Maximum Pressure That The XTerra Shield RP8 Column Can Tolerate?
This particular XTerra Shield RP8 Column has been designed to tolerate a maximum of 6,000 psi (415 Bar).