Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
MS C18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
125 Å |
Format |
Column |
Surface Area |
175 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
50 mm |
Carbon Load |
16 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Columns |
Units per Package |
1 pk |
XTerra MS C18 Column, 125Å, 5 µm, 3 mm X 50 mm, 1/pk
Add the reversed-phase, hybrid-based, general-purpose XTerra MS C18 Column to your collection of lab equipment. The first-generation analytical column offers greater pH stability than a silica-based column and is made to be compatible with mass spectrometry applications.
The XTerra MS C18 Column features sharp peak forms, good sensitivity, and huge peak capacities because it was made to work with Mass Spectrometry applications. By utilizing the tri-functional bonding chemistry of the XTerra particles, the lab equipment is able to give one of the longest lives over the largest pH range when compared to conventional silica-based columns. Additionally, the column offers exceptional resolution, extremely low column bleed, and maximum throughput.
The packing materials used in the XTerra MS C18 Column are created utilizing Waters Hybrid Particle Technology, and they combine the benefits of both inorganic (silica) and organic (organosiloxane) components to deliver a potent new solution. By utilizing this hybrid technology, the XTerra MS C18 column outperforms silica-based reversed-phase packing materials in terms of separation efficiency and pH stability.
Visit our website or peruse the catalog to discover additional XTerra goods as well as those that may be used in equipment with your top choices to give you a full set of lab supplies. Additionally, you can find information about how to get in touch with our personnel in each of our locations around the equipment as well as shop for lab equipment.
When the XTerra MS C18 column is made, the cleanliness and chemical composition of the hybrid particle are both controlled. The analytical column is made only from ultrapure reagents. Throughout the manufacturing process, the column is closely watched and checked against strict specifications. Each column is examined separately to guarantee that you only get the highest caliber lab equipment. Certificates of Batch Analysis and Column Efficiency are provided with each column so you can be sure of this quality.
You may also want to invest in the XTerra MS C18 VanGuard Cartridge, 125Å, 5 µm, 2.1 mm X 5 mm, 3/pk.
Across What pH Range Does The XTerra MS C18 Column Operate?
The XTerra MS C18 Column listed here offers a broad working pH range of 1-12.
What Is The Maximum Pressure That The XTerra MS C18 Column Can Sustain?
The XTerra MS C18 Column listed here has been designed to be able to take a maximum of 6000 psi (415 Bar) pressure.