Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
MS C18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
125 Å |
Format |
Column |
Surface Area |
175 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
50 mm |
Carbon Load |
16 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Columns |
Units per Package |
1 pk |
XTerra MS C18 Column, 125Å, 5 µm, 2.1 mm X 50 mm, 1/pk
The XTerra MS C18 Column is designed to be perfectly suited for Mass Spectrometry applications and delivers sharp peak forms, good sensitivity, and big peak capacities. When compared to conventional silica-based columns, the lab equipment uses the tri-functional bonding chemistry of the XTerra particles to give one of the longest lives over the widest pH range. This is in addition to offering the highest throughput, exceptional resolution, and extremely little column leakage.
Include the XTerra MS C18 Column in your collection of lab equipment. The analytical column is a general-purpose, hybrid-based, reversed-phase C18 column that was made to work with a variety of mass spectrometry applications. When compared to a silica-based column, the first-generation XTerra MS C18 Column can offer improved pH stability.
Waters Hybrid Particle Technology is used to create the XTerra packaging materials. These particles combine the benefits of both organic and inorganic materials by combining both inorganic (silica) and organic (organosiloxane) components. When compared to reversed-phase packing materials made of silica, the XTerra MS C18 Column delivers great separation efficiency and improved pH stability due to the employment of this hybrid technology.
The XTerra MS C18 Column is created with ultrapure reagents, much like all other lab equipment sold as being made by Waters, guaranteeing the control of the chemical composition and purity of the hybrid particle. Every stage of the production process is meticulously monitored, controlled, and done within very strict tolerances. To ensure that you only receive the highest caliber lab supplies, each column is additionally put through an individual test. Certificates of Batch Analysis and Column Efficiency are provided with each column to ensure that you have high-quality equipment.
We recommend that you employ the XTerra MS C18 VanGuard Cartridge, 125Å, 5 µm, 2.1 mm X 5 mm, 3/pk alongside the column. The cartridge prevents any chemical or particulate material from entering the mobile phase, improving your analysis results while increasing the lifespan of the column.
Does The XTerra MS C18 Column Have Any pH Limitations?
The Waters XTerra MS C18 Column listed here offers a broad working pH range of 1-12.
What Is The Maximum Pressure That The XTerra MS C18 Column Can Withstand?
This particular XTerra MS C18 Column has been designed to tolerate a maximum of 6,000 psi (415 Bar).