Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
MS C8 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
125 Å |
Format |
Column |
Surface Area |
175 |
System |
HPLC |
USP Classification |
L7 |
Inner Diameter |
3 mm |
Length |
150 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Columns |
Units per Package |
1 pk |
XTerra MS C8 Column, 125Å, 3.5 µm, 3 mm X 150 mm, 1/pk
The general-purpose, hybrid-based, reversed-phase C8 columns known as XTerra MS C8 columns are made to work with mass spectrometry applications. Comparing these first-generation columns to a silica-based column, they offer improved pH stability.
The fact that the XTerra Columns are created utilizing Waters Hybrid Particle Technology, and the particles contain both inorganic (silica) and organic components, delivering a potent mix of the advantages of both, is what distinguishes them from other products. When compared to the more traditional silica-based reversed-phase packing materials, this hybrid technology enables the XTerra MS C8 column to provide excellent efficiency of separation and better pH stability over a wide pH range (1–12).
The XTerra MS C8 Column, which is specifically made to work with Mass Spectrometry (MS) applications, will give you sharp peak forms, good sensitivity, and huge peak capacities. Along with the column's ability to deliver the highest throughput with exceptional resolution and extremely low column bleed, several qualities are mentioned.
Utilizing ultrapure reagents throughout the manufacturing process allows for complete control over the chemical makeup and purity of the hybrid particle in the XTerra MS C8 column. The XTerra MS C18 Column, like every other Waters column, is created in cutting-edge Waters facilities where each stage of production and packing is closely supervised and carried out within precise tolerances. To ensure you get lab equipment you can rely on and is of the highest quality, each column is manually inspected. Each column comes with Certificates of Batch Analysis and Column Efficiency to help you relax about the quality control standards. Prep-Guards, vials, and elution plates are just a few of the items that are compatible with the XTerra MS C8 Column that you may find on our website. You can shop for lab equipment from the Waters website, as well as contact them with any questions you might have. You can contact a member of our staff at one of our many offices across the world with these questions and concerns.
We also recommend having a look into XTerra MS C8 VanGuard Cartridge, 125Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk; XTerra MS C8 VanGuard Cartridges are used to enhance analytical column lifetime and performance by eliminating particle pollution from the mobile phase stream. All 2.1 mm and 3.0 mm I.D. XTerra MS C8 analytical columns with 3.5 µm sorbent particles are protected by this cartridge.
What Is The Relevance Of PTFE?
Polytetrafluoroethylene (PTFE) is a synthetic fluoropolymer of tetrafluoroethylene that has numerous applications within Liquid Chromatography.