Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
MS C18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
125 Å |
Format |
Column |
Surface Area |
175 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
16 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Columns |
Units per Package |
1 pk |
XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 150 mm, 1/pk
Designed to be compatible with Mass Spectrometry (MS) applications, the XTerra MS C18 Column offers sharp peak shapes, good sensitivity, and large peak capacities. By leveraging the tri-functional bonding chemistry of the XTerra particles, the XTeraa MS C18 Column delivers one of the longest column lifetimes over a wide pH range (1 - 12), especially when compared to conventional silica-based columns. These features are noted in addition to the column’s capacity to provide maximum throughput with outstanding resolution and ultra-low column bleed.
The XTerra packing materials are synthesized using Waters Hybrid Particle Technology, and the particles contain both inorganic (silica) and organic (organosiloxane) components, offering a powerful combination with the advantages of both. This hybrid technology makes it possible for the XTerra MS C18 column to provide you with high separation efficiency and improved pH stability in your lab results in contrast to silica-based reversed-phase packing materials.
The analytical column is a general-purpose, hybrid-based, reversed-phase C18 column that has been designed to be compatible with a range of mass spectrometry applications. The XTerra MS C18 Column is a first-generation column that can provide superior pH stability when compared to a silica-based column. As all the other lab equipment that is marketed as Waters’ manufactured, the XTerra MS C18 Column is made using ultrapure reagents, ensuring the control of the chemical composition and purity of the hybrid particle. The manufacturing is carefully monitored, and controlled every step of the way, and conducted within narrow tolerances. Each column is also individually tested to make sure you receive only the best quality lab equipment.
Add the XTerra MS C18 Column to your lab equipment collection. You can find additional products that are compatible with XTerra MS C18 Column, including guards, vials, elution plates, from our website. The website enables you to shop for lab equipment, as well as to reach out with any questions you may have. You can direct these queries and concerns to a member of our staff, located in one of our numerous offices located globally.
You might also be interested in XTerra MS C18 VanGuard Cartridge, 125Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk; which are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XTerra MS C18 analytical columns containing 3.5 µm sorbent particles.
What Is The pH Range And Pressure That The XTerra MS C18 Column Can Sustain?
The XTerra MS C18 Column is capable of operating within a pH range of 1 to 12 and can withstand pressures of up to 6000 psi (or 415 Bar).