Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Prep Column |
Surface Area |
335 |
System |
HPLC Preparative |
Technique |
LC/MS, LC |
USP Classification |
L1 |
Inner Diameter |
19 mm |
Length |
100 mm |
Carbon Load |
19 % |
UNSPSC |
41115709 |
Brand |
Symmetry |
Product Type |
Preparative Columns |
Units per Package |
1 pk |
Symmetry C18 Prep Column, 100Å, 5 µm, 19 mm X 100 mm, 1/pk
Preparative HPLC requires a separation tool that can easily overcome demanding chromatographic conditions, and the Symmetry C18 Prep Column can do exactly that and so much more. This general-purpose HPLC column offers a wide and usable pH range to accommodate varying analytes, while it can also handle pressures up to 6,000 PSI (415 Bar) while maintaining mechanical and chemical stability. Upgrade your HPLC separations with the Symmetry C18 Prep Column today, or tell your lab manager you want this helpful separation instrument at your command.
When you purchase and start using the Symmetry C18 Prep Column, you’ll immediately notice that this column delivers maximum reproducibility. Thanks to the rugged silica particle built into the column, you can rapidly reproduce separations and move on to the next stage of your workflow. Plus, thanks to Symmetry’s narrow column specification range, data variation is greatly minimized.
Want to protect your Symmetry C18 Prep Column from contamination?
First, follow proper sample purification protocols so you only have the cleanest samples running through your column. If any contaminants reach your analytical column, they have the capability to foul the inner lining. To prevent this, we’re here to offer a solution. Add the Symmetry C18 Prep Guard Cartridge to your workflow and you’ll be able to enhance your column’s overall lifetime. This HPLC guard cartridge filters out any contaminants in the mobile phase stream and integrates seamlessly into your existing workflow. Plus, this cartridge offers the same inner diameter and pH range as the Symmetry C18 Prep Column, making for a chemically and mechanically stable column protection solution.
At Waters, it’s truly our passion to provide scientists and laboratories across the world with the products, resources and solutions they need to be successful. From full LC-MS systems and lab informatics to quality control reference material and sample purification kits, you’ll find everything you need at Waters. Shop lab equipment to all of our offerings.
What is the Symmetry C18 Prep Column’s pH Range?
The Symmetry C18 Prep Column offers a range of 2 to 8 pH.