Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Method Validation Kit |
Surface Area |
335 |
System |
HPLC |
Particle Technology |
Silica |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
150 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
Symmetry |
Product Type |
Column Kits |
Units per Package |
3 pk |
Symmetry Silica Shield RP18 Method Validation Kit, 100Å, 3.5 µm, 4.6 mm X 150 mm, 3/pk
With the Symmetry Silica Shield RP18 Method Validation Kit, you will get excellent peak form over a wide pH range. The analytical column's wide pH range is made possible by its high bonding density and low levels of packing material silanol activity. This means that you can choose to optimize your procedure while maintaining the peak shape by working at neutral or low pH. In addition to this, the Symmetry Silica Shield RP18 Method Validation Kit's lower levels of detection and quantitation will accelerate the development of new techniques and increase laboratory productivity.
Visit our online store to discover additional comparable products and variations of the same product with different features. Additionally, you can learn more about our goods and the technologies we offer. Online lab equipment shopping is available, along with equipment on other applications for the products we offer.
Utilize the Symmetry Silica Shield RP18 Method Validation Kit's exceptional repeatability to take advantage of limited specification ranges. The lab equipment provides the industry's tightest ligand surface coverage (ligand density). As a result, there are fewer resolution shifts and more consistent results from batch to batch and column to column.
You may be sure that the Symmetry Silica Shield RP18 Method Validation Kit will last you a very long time and lower the cost of your lab equipment. This is so that the Symmetry Shield RP18 Column, which combines the hydrolytic stability of the packing material and the mechanical stability of the packed bed, can provide improved performance and a long column lifetime.
You may also want to explore and invest in the Symmetry Shield RP18 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk. The cartridge works in conjunction with the column and works by eliminating any chemical or particulate matter from the mobile phase. It enhances the lifetime of the column while delivering more reliable analysis results.
Across What pH Does The Symmetry Silica Shield RP18 Method Validation Kit Operate?
This particular Symmetry Silica Shield RP18 Method Validation Kit operates across the 2-8 pH range.
What Is The Maximum Pressure That The Symmetry Silica Shield RP18 Method Validation Kit Can Tolerate?
The Symmetry Silica Shield RP18 Method Validation Kit listed here can function well with up to a maximum of 6000 psi (415 Bar) pressure.