BioResolve SCX mAb, 3 μm, corrosion–resistant columns which contain non-porous, polymer-based particles grafted with a rigorously-optimized, multi-component network of negatively charged sulfonic acid ligands. This innovative column technology, delivers reproducible, high-resolution, charged-based separations of mAbs and other proteins in both LC and LC-MS applications using robust salt or pH gradient methods. This startup kit also includes one vial of the mAb Charge Variant Standard (P/N 186009065), one bottle of the BioResolve CX pH Concentrate A (pH 5.0) and one bottle of the BioResolve CX pH Concentrate B (pH 10.2), and two of the Certified LDPE 1000 mL Containers designed for use with Water BioResolve CX Buffer Concentrates.
Bonding Technology |
SCX |
Particle Shape |
Spherical |
QC Tested |
Protein |
Format |
Column |
System |
HPLC, UHPLC, UPLC |
Inner Diameter |
4.6 mm |
Length |
50 mm |
eCord |
Yes |
UNSPSC |
41115709 |
Application |
Protein |
Brand |
BioResolve |
Product Type |
Columns |
SCX Start Up Kit: BioResolve SCX mAb Column (4.6 mm X 50 mm) with VanGuard FIT plus mAb Standard plus pH Concentrates
At Waters, we’re always looking for ways to enhance your monoclonal antibody analyses. For an all-in-one solution kit for mAb assays, turn to the SCX Start Up Kit. This kit comes with two BioResolve SCX mAb Columns and one bottle each of BioResolve CX pH Concentrate A and B to maximize your time in the lab. And what’s more, this kit also comes with two Certified LDPE 1000 mL Containers and the mAb Charge Variant Standard for LC-MS system and instrument performance benchmarking purposes. Take your mAb analyses to the next level when you purchase the SCX Start Up Kit. Or, tell your lab manager today that you want BioResolve SCX mAb Column technology at your command.
In every SCX Start Up Kit are two BioResolve SCX mAb Columns. At the heart of these columns lies a group of non-porous, polymeric particles that are grafted onto a network of negatively charged sulfonic acid ligands. Not only does this provide enhanced selectivity for mAb separations, this facet also increases column performance greatly. This will come in handy for those trying to develop methods. And since the BioResolve SCX mAb Column is LC-MS system agnostic, you can use it with UHPLC, UPLC and HPLC systems.
Before performing any important mAb separations and analyses, it’s important to check your LC-MS systems and instruments for proper performance. That’s why we’re happy to include the Waters mAb Charge Variant Standard in this kit. You can use this standard to test your equipment for proper performance. Looking for ways to implement charge variant profiling using optical detection?
The SCX Start Up Kit comes with one bottle each of BioResolve CX pH Concentrate A and B for exactly that purpose. Plus, these pH concentrates are carefully optimized for use with cation-exchange columns and other cation-exchange technology.
Another important thing to consider when working with BioResolve SCX mAb Columns is overall column protection from contaminants. Although sample purification protocols remove the majority of contaminants, there could still be miniscule particles in the mobile phase stream. To meet this consideration, we’re happy to present the BioResolve SCX mAb VanGuard FIT Cartridge. Add this cartridge to your workflow for added protection.
Before checking out with your SCX Start Up Kit, make sure to explore all of the other incredible products and resources we have to offer at Waters. Shop lab equipment to explore everything we have to offer.
Does the SCX Start Up Kit Include an eCord?
Certainly.