Line drawing of a column

SKU: 176004171
BioResolve RP mAb Polyphenyl Method Validation Kit, 450Å, 2.7 µm, 4.6 mm X 150 mm, 3/pk

BioResolve RP mAb Polyphenyl Method Validation Kit | 4.6 x 150mm | 176004171


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

BioResolve RP mAb Columns contain 2.7-μm superficially-porous-silica particles having an average pore diameter of 450Å. The particles are functionalized with a proprietary polyphenyl bonding process that was specifically designed for LC or LC-MS analyses of intact IgG monoclonal antibodies and their fragments.  This Method Validation Kit Part Number contains (3) columns from (3) different manufactured batches.  This P/N also includes three vials of the Intact mAb Mass Check Standard (P/N 186006552) and three vials of the mAb Subunit Standard (P/N 186008927).

Specifications

  • Separation Mode

    Reversed Phase

  • Particle Size

    2.7 µm

  • Pore Size

    450 Å

  • UNSPSC

    41115709

  • Brand

    BioResolve

  • Product Type

    Column Kits

  • Units per Package

    3 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

BioResolve RP mAb Polyphenyl Method Validation Kit, 450Å, 2.7 µm, 4.6 mm X 150 mm, 3/pk

To properly validate your methods, you need to be able to rapidly reproduce to verify separations and data. And with the BioResolve RP mAb Polyphenyl Method Validation Kit, you can do exactly that and so much more. This all-in-one reverse-phase mAb analysis kit comes with three BioResolve RP mAb Polyphenyl Columns for your separations, three vials each of the Intact mAb Mass Check Standard and mAb Subunit Standard, and all the breakthrough column features you need to overcome demanding chromatographic conditions. What’s more, you can equip the BioResolve RP mAb Polyphenyl Column with VanGuard column protection technology designed to protect your data from variability caused by particulate contamination. Take your mAb analyses to the next level with the help of the BioResolve RP mAb Polyphenyl Method Validation Kit.

What makes the BioResolve RP mAb Polyphenyl Column so unique?
For one, the rugged silica particles inside are functionalized using a proprietary polyphenyl bonding process to make them more than ready to handle mAb separations. Not only that, but these functionalized particles enable this column to operate at lower temperatures for less on-column sample degradation. This especially comes in handy for method development scientists, as they need a flexible yet rugged separation tool to assist with their important assays.

As mentioned earlier, you can equip the BioResolve RP mAb Polyphenyl Columns with VanGuard technology to better protect your columns from contamination. All you have to do is purchase the BioResolve RP mAb Polyphenyl VanGuard Cartridge. This guard cartridge is specifically designed to incorporate seamlessly into your existing workflow to provide enhanced protection. And once it becomes worn and needs to be replaced, you can do so with another genuine replacement guard cartridge from Waters.

Shopping at Waters is about much more than just getting the right columns for your mAb analyses. We also offer a complete line of LC-MS and MS systems designed to take your lab to the future with enhanced separation and analysis technology. Plus, we offer everything you need to be successful in the lab, including solution kits, chromatography consumables, quality control reference materials and so much more. Shop lab equipment to explore our selection of products and resources.

Can the BioResolve RP mAb Polyphenyl Column Operate at Lower Temperatures?

Yes, the BioResolve RP mAb Polyphenyl Column is uniquely suited to operated at lower temperatures to prevent on-column sample degradation.