BioResolve RP mAb Columns contain 2.7-μm superficially-porous-silica particles having an average pore diameter of 450Å. The particles are functionalized with a proprietary polyphenyl bonding process that was specifically designed for LC or LC-MS analyses of intact IgG monoclonal antibodies and their fragments. This P/N also includes one vial of the Intact mAb Mass Check Standard (P/N 186006552) and one vial of the mAb Subunit Standard (P/N 186008927).
Separation Mode |
Reversed Phase |
Particle Size |
2.7 µm |
Pore Size |
450 Å |
UNSPSC |
41115709 |
Brand |
BioResolve |
Product Type |
Columns |
Units per Package |
1 pk |
BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 4.6 mm X 150 mm, 1/pk w/ Intact mAb and mAb Subunit Standards
Using reverse-phase chromatographic techniques for the analysis of monoclonal antibodies can sometimes present you with a few analytical challenges, but the BioResolve RP mAb Polyphenyl Column is here to help you overcome them all with ease. Not only does this mAb analysis column offer improved peak capacity for better component resolution, it also offers minimal injection-to-injection carryover for increased confidence in your analyses. What’s more, the BioResolve RP mAb Polyphenyl Column can be used on UHPLC, UPLC and HPLC systems with the same dedication to separation performance and selectivity. See how the BioResolve RP mAb Polyphenyl Column can change your assays for the better when you purchase one today.
To ensure you only receive a BioResolve RP mAb Polyphenyl Column that works properly right out of the box, each and every column we produce undergoes a strict QC process to verify performance. In particular, this column is tested with the mAb Subunit Standard to verify performance. This standard is a filtered and stabilized formulation of reduced, IdeS-digested NIST Reference Material 8671 (NIST mAb), and you can use this standard on your LC and LC-MS instruments to verify proper performance.
The BioResolve RP mAb Polyphenyl Column offers an innovative solution for the analytical characterization of interact protein analysis, as the novel phenyl bonding technology enables this column to provide higher flow rates. This is perfect for those performing protein analysis, as you can maximize the resolving power and selectivity of protein samples easily because of this. What’s more, the high-coverage bonding prevents carryover effects and increases low pH stability for better overall column lifetimes.
Protecting your BioResolve RP mAb Polyphenyl Column from contaminants should always be a top priority. And although proper sample purification protocols remove contaminants from your workflow, there still may be contaminants lingering in the mobile phase stream that could foul your column. To prevent these contaminants from entering your analyses, we’re happy to provide the BioResolve RP mAb Polyphenyl VanGuard Cartridge. This guard cartridge removes contaminants in the mobile phase stream as you’re performing separations.
Once you’ve added the BioResolve RP mAb Polyphenyl Column to your cart, make sure to shop lab equipment to discover all of the other incredible products and resources we have to offer. If you’re working with LC-MS and LC equipment, you’ll find that our offerings can help you be more successful in the lab.
What is the BioResolve RP mAb Polyphenyl Column’s pH Range?
The BioResolve RP mAb Polyphenyl Column offers a range of 2 to 7 pH.