Line drawing of a column

SKU: 176004166
BioResolve RP mAb Polyphenyl Method Validation Kit, 450Å 2.7 µm, 3 mm X 150 mm, 3/pk with Intact mAb and mAb Subunit Standards

BioResolve RP mAb Polyphenyl Method Validation Kit | 3 x 150mm | 176004166


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

BioResolve RP mAb Columns contain 2.7 µm superficially-porous-silica particles having an average pore diameter of 450 Å. The particles are functionalized with a proprietary polyphenyl bonding process that was specifically designed for LC or LC-MS analyses of intact IgG monoclonal antibodies and their fragments. This Method Validation Kit Part Number contains (3) columns from (3) different manufactured batches. This p/n: also includes one vial of the Intact mAb Mass Check Standard (p/n: 186006552) and one vial of the mAb Subunit Standard (p/n: 186008927). This is a Method Validation Kit that includes three (3) columns.

Specifications

  • Separation Mode

    Reversed Phase

  • pH Range Min

    2 pH

  • pH Range Max

    7 pH

  • Temperature Limits

    90 C

  • Maximum Pressure

    10000 psi (689 Bar)

  • Particle Size

    2.7 µm

  • Pore Size

    450 Å

  • QC Tested

    Protein

  • System

    HPLC, UHPLC, UPLC

  • USP Classification

    L11

  • Inner Diameter

    3 mm

  • Length

    150 mm

  • UNSPSC

    41115709

  • Application

    Protein

  • Brand

    BioResolve

  • Product Type

    Column Kits

  • Units per Package

    3 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

BioResolve RP mAb Polyphenyl Method Validation Kit, 450Å 2.7 µm, 3 mm X 150 mm, 3/pk with Intact mAb and mAb Subunit Standards

Validating methods during mAb analyses can sometimes be difficult, as you need to constantly reproduce and transfer methods when you need increased resolution. But with the BioResolve RP mAb Polyphenyl Method Validation Kit, you can take many of those difficulties out of your workflow. This all-in-one monoclonal antibody analysis kit comes with three BioResolve RP mAb Polyphenyl Columns for your separations and three vials each of the Inact mAb Mass Check and mAb Subunit Standards for system performance verification purposes. And if you want to add more protection against harmful contaminants, these columns can be equipped with VanGuard Cartridges. See how the BioResolve RP mAb Polyphenyl Method Validation Kit can take your mAb analyses to the next level when you purchase one for yourself today.

The BioResolve RP mAb Polyphenyl Column is specifically designed to provide you with the LC or LC-MS analyses of intact IgG monoclonal antibodies and their fragments. But how it achieves that is even more interesting. The superficially-porous-silica particles in this column are functionalized with a proprietary polyphenyl bonding process that makes mAb analyses possible, plus this column can be used on UHPLC, HPLC and UPLC systems. That kind of flexibility is greatly wanted across the world by scientists.

It’s very important to verify LC-MS or LC system performance before performing any mAb separations with the BioResolve RP mAb Polyphenyl Column. That’s why we’ve included three vials each of the Inact mAb Mass Check Standard and mAb Subunit Standard. You can use these vials to verify system and instrument performance, making you even more sure of this column’s performance when you’re hard at work developing separations.

Speaking of being hard at work, have you thought about overall column performance over time?
With the BioResolve RP mAb Polyphenyl VanGuard Cartridge added to your workflow, you’ll be able to better protect your analytical column from contaminants in the mobile phase stream, all adding up to a longer column lifetimes. Plus, when these cartridges need to be replaced, you can do so with another genuine replacement from Waters.

Once you’ve added the BioResolve RP mAb Polyphenyl Method Validation Kit to your cart, think critically about if you have everything you need to be successful in the lab. If you need quality control reference materials, chromatography consumables or even resources to improve your analytical workflow, we’re here to help. Shop lab equipment to see how Waters can help you be a better scientist.

How Do I Store the BioResolve RP mAb Polyphenyl Column for Future Use?

The BioResolve RP mAb Polyphenyl Column can be stored for future use in 100% acetonitrile. Do not store columns in highly aqueous mobile phases.