Separation Mode |
Reversed Phase |
pH Range Min |
2 pH |
pH Range Max |
7 pH |
Temperature Limits |
90 C |
Maximum Pressure |
10000 psi (689 Bar) |
Particle Size |
2.7 µm |
Pore Size |
450 Å |
QC Tested |
Protein |
System |
HPLC, UHPLC, UPLC |
USP Classification |
L11 |
Inner Diameter |
3 mm |
Length |
150 mm |
UNSPSC |
41115709 |
Application |
Protein |
Brand |
BioResolve |
Product Type |
Column Kits |
Units per Package |
3 pk |
BioResolve RP mAb Polyphenyl Method Validation Kit, 450Å 2.7 µm, 3 mm X 150 mm, 3/pk with Intact mAb and mAb Subunit Standards
Validating methods during mAb analyses can sometimes be difficult, as you need to constantly reproduce and transfer methods when you need increased resolution. But with the BioResolve RP mAb Polyphenyl Method Validation Kit, you can take many of those difficulties out of your workflow. This all-in-one monoclonal antibody analysis kit comes with three BioResolve RP mAb Polyphenyl Columns for your separations and three vials each of the Inact mAb Mass Check and mAb Subunit Standards for system performance verification purposes. And if you want to add more protection against harmful contaminants, these columns can be equipped with VanGuard Cartridges. See how the BioResolve RP mAb Polyphenyl Method Validation Kit can take your mAb analyses to the next level when you purchase one for yourself today.
The BioResolve RP mAb Polyphenyl Column is specifically designed to provide you with the LC or LC-MS analyses of intact IgG monoclonal antibodies and their fragments. But how it achieves that is even more interesting. The superficially-porous-silica particles in this column are functionalized with a proprietary polyphenyl bonding process that makes mAb analyses possible, plus this column can be used on UHPLC, HPLC and UPLC systems. That kind of flexibility is greatly wanted across the world by scientists.
It’s very important to verify LC-MS or LC system performance before performing any mAb separations with the BioResolve RP mAb Polyphenyl Column. That’s why we’ve included three vials each of the Inact mAb Mass Check Standard and mAb Subunit Standard. You can use these vials to verify system and instrument performance, making you even more sure of this column’s performance when you’re hard at work developing separations.
Speaking of being hard at work, have you thought about overall column performance over time?
With the BioResolve RP mAb Polyphenyl VanGuard Cartridge added to your workflow, you’ll be able to better protect your analytical column from contaminants in the mobile phase stream, all adding up to a longer column lifetimes. Plus, when these cartridges need to be replaced, you can do so with another genuine replacement from Waters.
Once you’ve added the BioResolve RP mAb Polyphenyl Method Validation Kit to your cart, think critically about if you have everything you need to be successful in the lab. If you need quality control reference materials, chromatography consumables or even resources to improve your analytical workflow, we’re here to help. Shop lab equipment to see how Waters can help you be a better scientist.
How Do I Store the BioResolve RP mAb Polyphenyl Column for Future Use?
The BioResolve RP mAb Polyphenyl Column can be stored for future use in 100% acetonitrile. Do not store columns in highly aqueous mobile phases.