Separation Mode |
Reversed Phase |
pH Range Min |
2 pH |
pH Range Max |
7 pH |
Temperature Limits |
90 C |
Maximum Pressure |
10000 psi (689 Bar) |
Particle Size |
2.7 µm |
Pore Size |
450 Å |
QC Tested |
Protein |
System |
HPLC, UHPLC, UPLC |
USP Classification |
L11 |
Inner Diameter |
3 mm |
Length |
100 mm |
UNSPSC |
41115709 |
Application |
Protein |
Brand |
BioResolve |
Product Type |
Column Kits |
Units per Package |
3 pk |
BioResolve RP mAb Polyphenyl Method Validation Kit, 450Å, 2.7 µm, 3 mm X 100 mm, 3/pk with Intact mAb and mAb Subunit Standards
Performing monoclonal antibody separations via LC-MS techniques is just one objective, while developing and validating methods with mAbs can be another thing entirely. But with the BioResolve RP mAb Polyphenyl Method Validation Kit, you can easily accomplish both of those things with a dedication to data integrity. This method validation kit includes three BioResolve RP mAb Polyphenyl Columns to perform your separations with and three vials each of the liquid chromatography standards you need to verify system performance with. These standards are the Intact mAb Mass Check Standard and the mAb Subunit Standard, two specially formulated mixes for use with LC-MS or LC instruments and systems. Take your monoclonal antibody analyses to the next level with the BioResolve RP mAb Polyphenyl Method Validation Kit.
How can you be sure of the performance of all three BioResolve RP mAb Polyphenyl Columns?
For one, all three columns are packed with the same material but from three different batches. And on top of that, all BioResolve RP mAb Polyphenyl Columns undergo strict QC testing before being packed and shipped directly to you. This strict QC testing process includes testing with the Intact mAb Mass Check and mAb Subunit Standards. This way we can ensure that you only receive our best products right out of the box.
The BioResolve RP mAb Polyphenyl Column is designed specifically for the quantitation of monoclonal antibodies from IgG monoclonal antibodies and their fragments. But how it achieves such a miraculous goal is through the porous silica particles inside the column. These particles are bonded using a novel phenyl bonding process, optimizing these particles for LC or LC-MS analyses of monoclonal antibodies. It even offers improved peak capacity for better component resolution. Another terrific facet that makes the BioResolve RP mAb Polyphenyl Column a popular choice among scientists for mAb analysis.
Protecting your assays from variability caused by column contamination should always be a top priority. To fully prevent contaminants in the mobile phase stream from entering your analytical column, we recommend using the BioResolve RP mAb Polyphenyl VanGuard Cartridge. This column protection cartridge removes contaminants from your analytical workflow and can be easily replaced when worn.
Shopping at Waters helps scientists across the world achieve their goals. From quality control reference materials and classic chromatography consumables to solution kits and resources to improve your workflows, we simply have it all. Shop lab equipment to discover everything we have to offer.
Does the BioResolve RP mAb Polyphenyl Method Validation Kit Come With an eCord Connector?
Yes.