Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Column |
Surface Area |
100 |
System |
UHPLC, UPLC |
Particle Technology |
Solid Core |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
6.4 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
3 pk |
CORTECS Shield RP18 Column, 90Å, 2.7 µm, 2.1 mm X 150 mm, 3/pk
Prioritize speed and efficiency during HPLC separations with the CORTECS Shield RP18 Column. This reversed-phase silica column offers complementary selectivity to C8 and C18 stationary phases, making it a top choice for scientists performing related assays. What’s more, this column was created using state-of-the-art column packing and end-capping techniques, ensuring that you get a chromatography consumable that’s truly up for any challenge. Flexibly develop methods for difficult separations better than ever before with the CORTECS Shield RP18 Column.
Producing a reliable data set that instills confidence in stakeholders is a huge objective to consider when you’re in the lab. That’s why you should only use equipment that prioritizes the importance of data confidence, which is why we’re proud to provide the perfect tool in the CORTECS Shield RP18 Column. And with technology in this column that prevents unwanted surface-analyte interactions during method development, paving a successful path to MS adoption is a certainty. This all adds up to a reversed-phase column that you can rely on.
The RP18 column chemistry is unique to chromatography consumables, as it includes an embedded carbamate group in the bonded phase ligand. This helps it to provide complementary selectivity to C8 and C18 stationary phases. Plus, if you’re using lower backpressures during your experiments or varying flow rates, that’s no concern to the CORTECS Shield RP18 Column. It’s uniquely suited to work under various conditions without harming signal intensity or efficiency.
CORTECS Columns were designed by Waters scientists to fulfill the need to get simple and seamless method transfer in liquid chromatographic applications. But even more than that, they provide consistent batch-to-batch results, resulting in easier method validation. Don’t need an RP18 column for your assays?
Shop CORTECS Columns to find the right match, and don’t forget to tell your lab manager about all of the benefits that CORTECS Columns can provide.
Need sample preparation elution plates or quality control reference materials?
At Waters, we’re your one-stop shop for LC-MS products and equipment, even including lab informatics. Shop for lab equipment to be better prepared for the science of tomorrow.
How Do I Clean the CORTECS Shield RP18 Column.
Flush the CORTECS Shield RP18 Column with 20 column volumes of neat organic solvent.