Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
T3 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
120 Å |
Format |
Column |
Surface Area |
100 |
System |
UPLC, UHPLC |
Particle Technology |
Solid Core |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
30 mm |
Carbon Load |
4.7 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
3 pk |
CORTECS Shield RP18 Column, 90Å, 2.7 µm, 3 mm X 150 mm, 1/pk
Phenolic compounds by nature can be difficult to separate even with optimal UPLC or HPLC conditions, which is why the CORTECS Shield RP18 Column has been designed to make those LC separations much easier. Not only does this RP18 column provide complementary selectivity to traditional C8 and C18 stationary phases, it also prevents unwanted analyte-surface interactions through innovation fostered by Waters scientists. This all adds up to a column that you can trust to have in your toolkit for many assays to come.
The embedded carbamate group in the bonded phase ligand within this CORTECS column makes this product unique and helps it to achieve the alternative selectivity scientists have come to expect from columns of similar particle morphology. Just compare the CORTECS Shield RP18 Column to straight chain alkyl columns to see that choosing CORTECS over the competition can result in desirable results, greater throughput, better selectivity and so much more. And if you’re operating with lower backpressures than is normal, that’s not a problem for the CORTECS Shield RP18 Column.
Seamless method transfer is also at the top of the want lists by scientists across the globe, which is why we’ve designed the CORTECS product line to include items that can help you pave the path toward MS adoption easily and without losses in peak signal intensity. As for the reliability of the CORTECS Shield RP18 Column, it’s worth noting that this piece of lab equipment offers plenty of features that protect it from signal loss as well. This can turn your lab into a more efficient and profitable asset to your company.
CORTECS columns are one of the many exciting product lines offered by Waters Corporation. These UPLC columnz are available in a wide variety of different pore sizes and selectivity options. That means no matter what compounds you need to separate and analyze, you should shop CORTECS Columns versus other options.
Providing HPLC columns and consumables is only a small part of everything we do at Waters Corporation. At our core, we’re developing products and services that make the life of a scientist much easier and more efficient. No matter if you need sample recovery vials, mobile phase bottles or full LC-MS systems, you’ll want to shop at Waters. Shop for lab equipment today so you’re better prepared for the experiments of tomorrow.
What Does the “RP” in CORTECS Shield RP18 Column Stand For?
“RP” stands for reversed-phase chromatography.