Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Column |
Surface Area |
100 |
System |
HPLC |
Particle Technology |
Solid Core |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
50 mm |
Carbon Load |
6.6 % |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
3 pk |
CORTECS C18 Column, 90Å, 2.7 µm, 4.6 mm X 50 mm, 3/pk
Benefit from adaptable lab equipment by adding the CORTECS C18 Column to your lab. The CORTECS C18 Column is made to be versatile and efficient. It is built around a solid-core particle that retains acids, bases, and neutrals in a balanced manner at low and mid-pH. You can acquire excellent peak shape for basic analytes at low pH because of the analytical column's characteristics.
You can browse our website or peruse our catalog to see additional variations of the listing here, as well as our whole selection of products to check our current offerings and shop for lab equipment.
The general-purpose, charged-surface CORTECS C18 Column helps resolve complicated combinations or retain resolution while improving throughput. Because the solid-core particles on which the CORTECS C18 Column is built provide improved performance by decreasing each of the three terms of the van Deemter equation, the column is able to offer such outstanding results. The A term decreases as the solid core particles pack more uniformly, while the B term decreases as the solid core particles have smaller particle porosity, reducing axial diffusion. Their solid core enhances heat transport and reduces radial temperature gradients, lowering the C term.
By simply increasing the flow rate of the technique, you can improve sample throughput while maintaining or improving peak capacity. It also enables the use of a shorter column length than the original separation while maintaining identical peak capacities and giving faster re-equilibration times. As a result, employing the CORTECS C18 Column can help you save money in the lab since it enables fast analysis without sacrificing separation performance, allowing you to analyze numerous samples in the same amount of time.
Enhance the lifetime of your lab equipment by using the CORTECS C18 VanGuard Cartridge, 90Å, 2.7 µm, 3.9 mm X 5 mm, 3/pk, which ensures that the analytical column lasts a long time and delivers consistent findings. This is accomplished by shielding the column from any particle or chemical contamination, preserving the column's analytical capabilities and ensuring consistent findings.
What Is The pH Range Offered By The CORTECS C18 Column?
The CORTECS C18 Column offered an operating pH range of 2-8.
What Are The CORTECS C18 Column’s Temperature Limits?
The CORTECS C18 Column listed here can tolerate up to 45 C temperature.