Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.6 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Column |
Surface Area |
100 |
System |
UHPLC, UPLC |
Particle Technology |
Solid Core |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
30 mm |
Carbon Load |
6.6 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
3 pk |
CORTECS C18 Column, 90Å, 1.6 µm, 2.1 mm X 30 mm, 3/pk
The general-purpose, charged-surface CORTECS C18 Column helps resolve complicated combinations or retain resolution while improving throughput. Because the solid-core particles on which the CORTECS C18 Column is built provide improved performance by decreasing each of the three terms of the van Deemter equation, the column is able to offer such outstanding results. The A term decreases as the solid core particles pack more uniformly, while the B term decreases as the solid core particles have smaller particle porosity, reducing axial diffusion. Their solid core enhances heat transport and reduces radial temperature gradients, lowering the C term.
Add the CORTECS C18 Column to your lab to take advantage of the equipment's versatility. The CORTECS C18 Column is a piece of general-purpose lab equipment that produces high-efficiency results. It is built on a solid-core particle that retains acids, bases, and neutrals in a balanced manner at low and mid-range pH. You can acquire excellent peak shape for basic analytes at low pH because of these characteristics of the analytical column.
By simply increasing the flow rate of the technique, you can improve sample throughput while maintaining or improving peak capacity. It also enables the use of a shorter column length than the original separation while maintaining identical peak capacities and giving faster re-equilibration times. As a result, employing the CORTECS C18 Column can help you save money in the lab since it enables fast analysis without sacrificing separation performance, allowing you to analyze numerous samples in the same amount of time.
We recommend that you also explore the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. The lab equipment enables you to store your solvents, solutions, and samples in a safe and chemically inert environment to get the most reliable analysis results. Waters offers the only vials chemically tested and certified for the LC and LC/MS Analysis. The preslit PTFE/Silicone septa are ideal for numerous injections and sample storage because of its excellent resealing capabilities. Additionally, to assure cleanliness and quality, each batch of vials is checked after being packaged for many days.
What Pressure Can The CORTECS C18 Column Tolerate?
The CORTECS C18 Column listed here is able to work well with up to a maximum of 18000 psi (1240 Bar) pressure.