Chemistry |
C18 |
|
Separation Mode |
Reversed Phase |
|
Particle Substrate |
Silica |
|
pH Range Min |
2 pH |
|
pH Range Max |
8 pH |
|
Maximum Pressure |
18000 psi (1240 Bar) |
|
Endcapped |
Yes |
|
Silanol Activity |
Low |
|
Particle Shape |
Spherical |
|
Particle Size |
2.5 µm |
|
Endfitting Type |
Parker-style |
|
Pore Size |
100 Å |
|
Format |
Column |
|
Surface Area |
230 |
|
System |
UPLC, UHPLC |
|
Particle Technology |
HSS |
|
USP Classification |
L1 |
|
Inner Diameter |
3 mm |
|
Length |
150 mm |
|
Carbon Load |
15 % |
|
eCord |
Yes |
|
UNSPSC |
41115709 |
|
Brand |
XSelect |
|
Product Type |
Columns |
|
Units per Package |
3 pk |
XSelect HSS C18 Column, 100Å, 2.5 µm, 3 mm X 150 mm, 3/pk
Complicated mixtures of basic and non-basic substances can be separated using the XSelect HSS C18 Column, which is well suited for separations with low pH. The High Strength Silica (HSS) technology found in lab equipment was created specifically to provide benefits to chromatography, such as improved polar component retention and enhanced selectivity. The HSS particle also provides the required mechanical strength for enduring UPLC pressures. Because of this, you receive alternate analyte selectivity when comparing the XSelect HSS C18 Column to the most recent, high coverage, fully end-capped C18 columns. Additionally, it is completely transferrable to UPLC separations and scalable.
Choose the all-purpose C18 bonded phase XSelect HSS C18 Column to obtain superior peak shape for basic chemicals, enhanced retention (vs. XBridge C18 columns), and outstanding column lifetimes at low pH. The selectivity and retention seen using lab equipment is similar to that of the majority of contemporary, completely end-capped, high-coverage C18 columns made of silicon. The XSelect HSS C18 Column also demonstrates minimum column bleed, great batch-to-batch consistency, ultra-efficiencies, and seamless column format conversion. As a result, you can benefit from the XSelect HSS C18 Column's adaptability in meeting all of your analytical demands.
For complicated samples, higher resolution separations are necessary in order to identify and quantify the sample's contents. By utilizing the combined efficiency and selectivity of the XSelect HSS C18 Column, you may improve the resolution of extremely complex samples. Furthermore, the XSelect HSS C18 Column can be trusted to give improved selectivity for acidic, alkaline, and neutral compounds, as well as improved retention for basic polar compounds when utilizing low-pH mobile phases.
Prevent any chemical or particulate matter from entering the mobile phase by using the XSelect HSS C18 XP VanGuard Cartridge, 100Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk. The cartridge is manufactured using the exact packing materials that are present in the column and is, therefore, ideally suited to the column. It enhances the lifetime of the column while delivering more accurate results.
What Is The Maximum Pressure Offered By The XSelect HSS C18 Column?
The Waters XSelect HSS C18 Column listed here is able to sustain a maximum of 18000 psi (1240 Bar) pressure.
What Are The pH Limitations Of The XSelect HSS C18 Column?
This particular XSelect HSS C18 Column offers a working pH range of 2-8 pH.