Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
T3 |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
230 |
System |
UPLC, UHPLC |
Particle Technology |
HSS |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
75 mm |
Carbon Load |
11 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
XSelect |
Product Type |
Columns |
Units per Package |
3 pk |
XSelect HSS T3 Column, 100Å, 2.5 µm, 2.1 mm X 75 mm, 3/pk
With the XSelect HSS T3 Column, you can retain polar molecules more effectively than with the conventional C18 phase. When utilizing up to 100% aqueous mobile phases, the reversed-phase analytical column performs better. The XSelect HSS T3 Column has the widest retention capabilities for combinations of polar and non-polar chemicals when employing conventional reversed-phase mobile phases.
Choose the XSelect HSS T3 Column, which is a low-coverage C18 phase compatible with 100% aqueous mobile phase, if you require a clear-cut first option when developing separations for polar and non-polar substances. The lab equipment is completely scalable and transportable to UPLC separations, and it demonstrates extremely little MS bleed.
The XSelect HSS T3 Column can improve selectivity for substances that are acidic, alkaline, and neutral in your lab. By using the XSelect column, you can take advantage of the special synergy of selectivity and efficiency to improve the resolution of extremely complex samples while saving you important time and effort when constructing a chromatographic test. When compared to BEH and CSH particles, the enhanced silanophilicity of the HSS particle offers benefits, including improved polar compound retention and noticeably different selectivity. In addition to this, the XSelect HSS XP Column offers exceptional repeatability and transferability.
The XSelect HSS T3 Column is likewise made to the highest industry standards in a cGMP, ISO 9001 certified plant using ultra-pure reagents, much like other Waters lab equipment. Every column is additionally tested individually to guarantee that you only get high-quality goods that produce accurate and repeatable results.
Shop for lab equipment from us directly and add products such as the TruView LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. Vials that are TruView LCMS Certified are made using strictly regulated manufacturing and handling techniques. Mass spectrometers are used to check for cleanliness, and ACQUITY/MS/MS is used to check for low analyte adsorption.
What Carbon Load Is Offered By The Waters XSelect HSS T3 Column?
The Waters XSelect HSS T3 Column listed here carries a carbon load of 11 %.
What Is The Maximum Pressure Recommended For Use With The XSelect HSS T3 Column?
This particular Waters XSelect HSS T3 Column is able to tolerate a maximum of 18000 psi (1240 Bar) pressure.