Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UPLC, UHPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
75 mm |
Carbon Load |
17 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
3 pk |
XBridge BEH Shield RP18 XP Column, 130Å, 2.5 µm, 2.1 mm X 75 mm, 3/pk
Change the way you perform reverse-phase HPLC method development forever and for the better with the XBridge BEH Shield RP18 XP Column. This RP18 column complements the standard XBridge C18 and C8 phases, making it a terrific choice for scientists who need alternate selectivity. Plus, the eXtended Performance (XP) column format enables exceptional separation performance and the flexibility you need to pave a path toward UPLC adoption. What’s more, all XBridge Columns offer MaxPeak HPS technology that helps to prevent the need to constantly reproduce to validate methods. Upgrade your HPLC method development assays with the XBridge BEH Shield RP18 XP Column today!
The XBridge BEH Shield RP18 XP Column comes chock full of features to make method development faster, easier and with reduced need for reproducibility. Part of how that is achieved is through the embedded carbamate group in the bonded phase ligand. If you’re working with phenolic compounds, you’ll find that the alternate selectivity caused by the carbamate group is designed just for you. Plus, this RP18 HPLC column is packed in ultra-low dispersion hardware that promotes the robustness you want to see from method development.
Enabling a seamless transition path toward UPLC adoption is one of the major benefits that the XBridge BEH Shield RP18 XP Column provides time and time again. But did you know that all XBridge Columns are designed to assist method development?
Make sure to check out our full selection of XBridge Columns to see if there are any other column configurations uniquely suited for your chosen applications.
It’s incredibly important to keep your XBridge BEH Shield RP18 XP Column clean and safe from contaminants. Although proper column cleaning and regeneration procedures take care of that, there’s still a chance for contaminants in the mobile phase stream to foul your column over time. To keep your column from fouling, we recommend pairing it with the XBridge BEH Shield RP18 XP VanGuard Cartridge. This guard cartridge removes those harmful contaminants from the mobile phase stream before they enter your analytical workflow
No matter which HPLC column you choose from Waters, you’re guaranteed to be receiving a chromatography product designed to help you be as successful as possible in the lab. But did you know that we also offer quality control reference materials, lab informatics and full LC-MS systems?
Shop lab equipment to explore our massive selection of products and resources.
What Does eXtended Performance (XP) Column Technology Mean?
eXtended Performance (XP) column technology describes the ultra-low dispersion column hardware used to produce select HPLC columns available at Waters Corporation. XP tech also helps to bridge the gap between HPLC and UPLC technology, enabling a seamless transition path whenever needed.