Chemistry |
PFP/Fluoro-Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
8 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Bonding Technology |
Fluoro-Phenyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
CSH |
USP Classification |
L43 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
10 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
3 pk |
ACQUITY UPLC CSH Fluoro-Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk
Utilize outstanding selectivity for positional isomers, halogenated compounds, and polar compounds by opting for the ACQUITY UPLC CSH Fluoro-Phenyl Column. This is made possible due to the combination of multiple retention mechanisms that include dipole-dipole, hydrogen-bonding, aromatic (pi-pi) as well as hydrophobic interactions.
Designed to maximize selectivity differences, the ACQUITY CSH Fluoro-Phenyl column provides maximum method development freedom, especially when using low pH mobile phases. The non-end-capped sorbent provides you with enhanced retention of acidic compounds, especially when compared to traditional PFP-bonded stationary phases.
The ACQUITY UPLC CSH Fluoro-Phenyl Column was developed by Waters, the top specialist measurement company in the world, in response to customer feedback received at multiple client forums. Using the subsequent development in particle technology, Waters created the Charged Surface Hybrid (CSH) Technology, the primary mechanism for the ACQUITY UPLC CSH columns. Shop for lab equipment on our website and look into further varieties of the item featured here. By opting to purchase from our online store, you will guarantee that you receive authentic Waters lab equipment.
The ACQUITY packing materials are produced in a cGMP, ISO 9001-certified facility using ultra-pure reagents and were created expressly for use with the ACQUITY UPLC System. To ensure repeatable performance, each batch of ACQUITY UPLC CSH Fluoro-Phenyl Column packing material is chromatographically tested with acidic, basic, and neutral analytes, and the results are held to limited specification ranges. On the eCordTM Intelligent Chip, a Performance Chromatogram and Certificate of Batch Analysis are supplied after each lab equipment has undergone an individual test.
Filter out any unwanted chemical or particulate contaminants from the mobile stream by using the ACQUITY UPLC CSH Fluoro-Phenyl VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk. The pre-column works in conjunction with the column and is an ideal fit for it as it is made using the exact packing materials that are present in the column.
Across What pH Range Does The ACQUITY UPLC CSH Fluoro-Phenyl Column Operate?
The Waters ACQUITY UPLC CSH Fluoro-Phenyl Column listed here is able to function well across the 1-8 pH range.
What Is The Maximum Pressure That The ACQUITY UPLC CSH Fluoro-Phenyl Column Can Tolerate?
This particular ACQUITY UPLC CSH Fluoro-Phenyl Column has been designed to be able to withstand up to 18,000 psi (1240 Bar) pressure.