Chemistry |
HILIC |
Separation Mode |
Hydrophilic Interaction (HILIC) |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
9 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L3 |
Inner Diameter |
3 mm |
Length |
100 mm |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
3 pk |
ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk
In ACQUITY UPLC BEH HILIC columns, which are intended to retain and separate very polar compounds, an unbonded BEH substrate is employed. These one-of-a-kind columns have been created and tested to enable effective, repeatable separations under HPLC HILIC conditions. Longer column lifetimes derive from the BEH particle's higher durability compared to HILIC phases based on silica.
The ACQUITY UPLC BEH HILIC Column makes use of Hydrophilic-Interaction Chromatography (HILIC), an additional chromatographic technique that can successfully enhance the retention of extremely polar species. Additionally, it offers an orthogonal separation mode for chemical combinations that are both polar and ionizable. This is accomplished by eluting the analytes with a polar stationary phase and a low-aqueous, acetonitrile-rich mobile phase in decreasing order of hydrophilicity.
To achieve unmatched levels of effectiveness, peak symmetry, and chemical stability, use the ACQUITY UPLC BEH HILIC Column. The analytical column offers very low and high pH stability for highly polar analytes. The user of the ACQUITY UPLC BEH HILIC Column can benefit from a wide pH range in the mobile phase (1-9). Additionally, the analytical column has an operating pressure of up to 18,000 psi for deeper examination (1240 bar).
The unique ACQUITY UPLC BEH HILIC Column has been created and demonstrated to deliver effective, trustworthy separations under HPLC HILIC conditions. Unbonded BEH substrates are used in the lab apparatus, which is intended to hold and separate very polar compounds. By coupling the chemical stability of BEH particles with silica-based HILIC phases, long column lifetimes are made possible. Use the ACQUITY UPLC BEH HILIC Column to affect the retention, selectivity, and sensitivity of ionizable chemicals. Outstanding performance is the consequence of the packing materials in the ACQUITY UPLC BEH HILIC Column being created specifically for use with the ACQUITY UPLC System.
You may want to shop for lab equipment to meet all of your laboratory needs by browsing our brochure or website. You might be interested in the ACQUITY UPLC BEH HILIC VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk; the ACQUITY BEH HILIC words describe unbonded BEH substrate and are made to hold and separate very polar compounds. By immediately connecting to the ACQUITY UPLC column's intake, the VanGuard pre-column minimizes superfluous column volumes and reduces leaking by doing away with extra connections.