SKU: 176001804
ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk

ACQUITY UPLC BEH Shield RP18 Column | 176001804


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    1.7 µm

  • Endfitting Type

    Parker-style

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    100 mm

  • Carbon Load

    17 %

  • eCord

    Yes

  • UNSPSC

    41115709

  • Brand

    ACQUITY UPLC

  • Product Type

    Columns

  • Units per Package

    3 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk

Utilize the ACQUITY Shield RP18 Column's peak shape enhancement capabilities and high-resolution strength for basic chemicals to provide good results because the lab equipment has special chemistry that provides complimentary selectivity to a C18 column. This performance is provided by the analytical column, which is also compatible with completely aqueous mobile phases. The embedded-polar group (carbamate) in the ACQUITY UPLC BEH Shield RP18 Column combines the hydrophobicity of a straight-chain-alkyl ligand (C18) with the hydrophilicity of an embedded polar group to give the column a distinct advantage for producing excellent results, particularly for phenolic compounds. In addition, the ACQUITY BEH Shield RP18 Column is a crucial and effective tool for developing HPLC methods, complementing the ACQUITY BEH C18 and C8 phases.

By adding an embedded carbamate into the bonded phase ligand, you can take advantage of the unique position of the ACQUITY UPLC BEH Shield RP18 Column that combines elements of Waters patented Shield Technology with BEH technology. With this combination, the inserted polar group ligand offers you alternative selectivity and an exceptional peak shape. Additionally, you get to deal with a broad pH range and the 1.7 µm BEH particle's ultra-efficiency. The ACQUITY UPLC BEH Shield RP18 Column is the pinnacle of lab equipment due to these characteristics.

Visit our website to find out more about the full selection of products sold under the ACQUITY name. Information on the goods, accessories that work with them, and enabling technologies may all be found on the website. You can also buy lab equipment straight from us through the internet.

We recommend that you also invest in the ACQUITY UPLC BEH Shield RP18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk in order to ensure that your column lasts a long time and that it continues to deliver optimally. The pre-column attaches to the analytical column and prevents any contaminants from reaching the mobile stream.

What Is The ACQUITY UPLC BEH Shield RP18 Column's Acceptable pH Range?

The ACQUITY UPLC BEH Shield RP18 Column listed here offers a pH range of 2-11.

What Is The Maximum Pressure For The ACQUITY UPLC BEH Shield RP18 Column?

The Waters ACQUITY UPLC BEH Shield RP18 Column is able to work well with a maximum of 18,000 psi (1240 Bar) pressure.