Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
150 mm |
Carbon Load |
18 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
3 pk |
ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 3 mm X 150 mm, 3/pk
The ACQUITY UPLC BEH C18 Column is designed to address a wide range of laboratory and technique requirements as well as chromatographic issues. The column aids in the improvement of your analysis' resolution, sensitivity, and speed. The ACQUITY UPLC BEH C18 Column can help you achieve a variety of goals with your research, including ultra-fast analysis, enhanced throughput while preserving resolution, and improving resolution while decreasing analysis time.
Because the analytical column is tri-functionally bonded, the ACQUITY UPLC BEH C18 Column is well suited to evaluate a wide range of analytes and can be utilized as a universal method development tool. It allows you to obtain remarkable pH stability for all analyte types, both low and high.
You may obtain remarkable analysis with the ACQUITY UPLC BEH C18 Column, which offers an industry-leading mobile phase pH range (1 - 12) and high-temperature stability (80 °C). For high sensitivity MS applications, the tri-functionally bound BEH particle on which the column is built provides the widest usable pH range (pH 1-12), better low pH stability, and ultra-low column bleed. The ACQUITY UPLC BEH C18 Column will have a direct impact on the retention, selectivity, and sensitivity of ionizable chemicals in your system. The packing materials used in the column were specifically engineered for use with the ACQUITY UPLC System, resulting in remarkable results.
You can shop for lab equipment from our website or by browsing through our detailed brochure to find all your requirements and needs for running tests and analysis in your laboratory.
We also recommend that you to check out ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk; As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The tri-functionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column, which minimizes extra column volumes and reduces leaking by eliminating additional connections.
What Is The pH Range And Pressure At Which The ACQUITY UPLC BEH C18 Column Can Operate On?
The ACQUITY UPLC BEH C18 Column is safe to use in a pH range of 1 to 12 and at pressures up to 18,000 psi (or 1240 Bar).