Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
30 mm |
Carbon Load |
18 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
3 pk |
ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 3 mm X 30 mm, 3/pk
Opt for the versatile ACQUITY UPLC BEH C18 Column to reach previously unheard-of levels of efficiency, peak symmetry, and chemical stability. A variety of analytes can be analyzed using the lab's equipment. The analytical column can be used as a general tool for developing methods because it is tri-functionally bonded. It provides exceptionally low and high-pH stability delivery for all analyte types. Utilizing the industry-leading mobile phase pH range and high-temperature stability of the ACQUITY UPLC BEH C18 Column will enable you to perform exceptional analysis. The trifunctionally bonded BEH particle gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.
Browse our website to locate the full range of our ACQUITY products, including the analytical columns and their guards. The website will also point you in the direction of complementary items that can be utilized with the columns to round out your analytical capabilities and to shop for lab equipment.
To affect the retention, selectivity, and sensitivity of chemicals that can be ionized, use the ACQUITY. The ACQUITY UPLC BEH C18 Column's packing components were created especially for use with the ACQUITY UPLC System. The analytical column is made in a cGMP, ISO 9001 certified facility utilizing ultra-pure reagents, much like the rest of our lab equipment. In order to ensure that the anticipated excellent, reproducible performance is achieved, each batch of ACQUITY UPLC BEH C18 Column packing material is tested chromatographically with acidic, basic, and neutral analytes. You may be sure of the performance of each column because a Performance Chromatogram and a Certificate of Batch Analysis are provided by the eCordTM Intelligent Chip.
We recommend that you protect your column by using the ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk. The pre-column prevents any unwanted contaminants from entering the mobile phase and thus, increase the accuracy of the results as well as increase the column's lifetime.
Across What pH Does The ACQUITY UPLC BEH C18 Column Perform?
The ACQUITY UPLC BEH C18 Column listed here is able to function well across a broad pH limit of 1-12.
What Is The Maximum Pressure That The ACQUITY UPLC BEH C18 Column Can Sustain?
The ACQUITY UPLC BEH C18 Column listed here can sustain a maximum of 18000 psi (1240 Bar) pressure.