Number of Analysis |
96 |
Type |
Sample Preparation Workflow |
Separation Mode |
HILIC |
Detection Method |
MS, MS/MS, UV, HRMS |
Storage Condition |
Refer to the storage recommendations of each sub-package |
System Type |
LC-MS |
Shelf Life |
Refer to the storage recommendations of each sub-package |
UNSPSC |
41116104 |
Application |
Glycan |
Brand |
GlycoWorks |
Product Type |
Application Kits |
Units per Package |
1 pk |
GlycoWorks RapiFluor-MS N-Glycan Script Parameters Starter Kit - Automation
To reimagine the workflow for N-Glycan analysis, Waters scientists went back to the essentials and created a purpose-built application kit to streamline that aforementioned analysis. And if you’re using automation equipment, Waters has developed an application kit to suit with the GlycoWorks RapiFluor-MS N-Glycan Script Parameters Starter Kit - Automation. This starter kit comes everything you need to properly perform glycan detection with the added benefit of having unmatched fluorescent and mass spectrometric performance. What’s more, this kit is specifically designed for use with automated platforms to achieve your glycan detection goals. This will help you achieve minimal user intervention as you automate this essential process. Add the GlycoWorks RapiFluor-MS N-Glycan Script Parameters Starter Kit – Automation to your lab’s toolkit now, or ask your lab manager to add this application kit to your lab’s next order from Waters.
The RapiFluor-MS Label provides unprecedented mass spectral signal intensity, which is huge when you’re performing glycan analysis. But even more, this label gives you the capability to easily assign low abundance glycans by serial fluorescence and mass spectrometric performance. To take full advantage of this breakthrough label, we recommend purchasing the GlycoWorks RapiFluor-MS N-Glycan Script Parameters Starter Kit – Automation.
What’s in the GlycoWorks RapiFluor-MS N-Glycan Script Parameters Starter Kit – Automation?
This kit includes everything needed to perform N-Glycan analysis, including the deglycosylation module, labeling module, clean-up module and sample collection module. This kit also includes a RapiFluor-MS Quantitative Glycan Standard, column and mobile phase concentrate which are the recommended for use with the RapiFluor-MS Library.
Before you check out with the GlycoWorks RapiFluor-MS N-Glycan Script Parameters Starter Kit – Automation, look around your lab to see if any essentials need to be restocked or refilled. That way you can place one order from Waters and have everything delivered together. Shop lab equipment to explore our entire selection of lab essentials.
What is the purpose of the GlycoWorks RapiFluor-MS N-Glycan Script Parameters Starter Kit – Automation?
This starter kit is designed for high-throughput, automated sample preparation of N-linked glycans from glycoproteins. It enables minimal user intervention while maintaining reliable, reproducible results, especially in regulated environments or large-scale biopharmaceutical workflows.
Which glycoproteins has this kit been validated for?
The protocol included in this kit has been validated using monoclonal antibodies (mAbs) and has demonstrated broad compatibility with a wide range of N-linked glycoproteins, making it suitable for both discovery and QC applications.
What automation platforms are compatible with this kit?
The kit is compatible with various liquid handling platforms. It includes a script parameters guideline and detailed liquid class table to aid with script development on non-Tecan automation platforms, offering high flexibility for labs using different robotic systems.
What is included in the starter kit?
The kit includes:
Why is the RFMS-labeled standard included in the kit?
The RFMS-labeled standard ensures accurate system suitability, data normalization, and method reproducibility during LC-FLR-MS glycan analysis. It plays a critical role in quality control and comparability across batches and studies.
How does this kit support high-throughput environments?
The pre-measured, automation-friendly reagent format and comprehensive scripting tools reduce hands-on time and optimize consistency. This is especially useful for labs needing scalable solutions for glycan profiling and characterization.
Explore more lab equipment and automation solutions ›
Looking for a compatible glycan enrichment module? Check out the GlycoWorks HBE Glycan Enrichment Cartridges, 30 mg, 1 mL, 30/pk.
How Many Analyses Can You Perform with the GlycoWorks RapiFluor-MS N-Glycan Script Parameters Starter Kit – Automation?
The GlycoWorks RapiFluor-MS N-Glycan Script Parameters Starter Kit – Automation comes with enough components to sustain 96 analyses.