Xevo TQ-S micro Triple Quadrupole Mass Spectrometer

Xevo TQ-S micro Triple Quadrupole Mass Spectrometer

Defining compact performance - robust sensitivity beyond expectation

Defining compact performance - robust sensitivity beyond expectation

From the inherently robust Xevo family of tandem quadrupole instruments, the Xevo TQ-S micro provides superior performance per square inch and exceptional analytical flexibility. Designed with your quantitative analysis and sample throughput in mind, explore how the Xevo TQ-S micro can benefit your laboratory in achieving high quality analytical data, injection after injection, in compliance with your regulatory, accreditation and quality requirements. Reliable instrument operation maximizes laboratory efficiency, delivering outstanding sensitivity for such a compact instrument.

Xevo TQ-S micro tandem quadrupole mass spectrometer Xevo TQ-S micro Triple Quadrupole Mass Spectrometer

Specifications

API sources and ionization modes

High performance ZSpray dual-orthogonal API sources:

1) Multi-mode source – tool-free ESI/APCI/ESCi™* (standard)

NB – Dedicated APCI requires an additional probe (optional)

2) UniSpray™ ion source (optional)

3) Tool-free APCI probe (optional)

4) nanoFlow™ ESI source* (optional)

5) ASAP* (optional)

6) APGC ion source (optional)

7) ionKey™/MS™ source* (optional)

Optimized gas flow dynamics for efficient ESI desolvation

Tool-free source exchange

Vacuum isolation valve

Tool-free access to customer serviceable elements

Plug-and-play probes

De-clustering cone gas

Software control of gas flows and heating elements

UniSpray ion source option

UniSpray is an ionization technique designed to broaden the scope of compounds which can be analyzed in a single run, including those which typically optimize in ESI, APCI or APPI. Enhanced ionization efficiency and desolvation allow the potential to combine several methodologies into one, or simply enable the operator to keep the same source for multiple methods, requiring less time performing set-up and routine maintenance, and more time delivering results

Ion source transfer optics

StepWave ion transfer optics delivering class leading UPLC™-MS/MS sensitivity. The unique off-axis design dramatically increases the efficiency of ion transfer from the ion source to the quadrupole MS analyzer at the same time as actively eliminating undesirable neutral contaminants

Mass analyzer

Two high resolution, high stability quadrupole analyzers (MS1/MS2), plus pre-filters to maximize resolution and transmission while preventing contamination of the main analyzers

Collision cell

T-Wave™ enabled for optimal MS/MS performance at high data acquisition rates

Detector

Low noise, off axis, long life photomultiplier detector

Vacuum system

One split-flow air-cooled vacuum turbomolecular pump evacuating the source and analyzer

One vacuum backing pump

Dimensions

Width: 35.6 cm (14.0 in)

Height: 60.0 cm (23.6 in)

Depth: 93 cm (36.6 in)

Regulatory approvals/marks

CE, CB, NRTL (CAN/US), RCM

Software

Systems supported on waters_connect and MassLynx™ version 4.2 or later

System setup and method development

System parameter checking and alerts

Integrated sample/calibrant delivery system + programmable divert valve

Automated mass calibration

Automated sample tuning

Automated MRM method development

UPLC-MS/MS System Check – automated on-column performance test

Automated MRM scheduling

(acquisition window assignment)

Dwell time, inter-channel delay time, and inter-scan delay time for individual channels in a multiple MRM experiment can be automatically assigned (using the Auto-Dwell feature) to ensure that the optimal number of MRM data points per chromatographic peak is acquired. The Auto-Dwell feature can dynamically optimize MRM cycle times to accommodate retention time windows that either partially or completely overlap.This greatly simplifies MRM method creation, irrespective of the number of compounds in a single assay, while at the same time ensuring the very best quantitative performance for every experiment

waters_connect Software

The waters_connect Software provides a modern user experience with a HUB design and apps that provide a consistent connected user experience across all applications. It is built for applications with convenient access to scientific apps allowing accelerated time-to-results and result quality. There are common utilities that complete the end-toend workflow and help increase productivity and efficiency. Confidently report results with accurate, reliable, regulation-standard data from application-focused quantitative workflows with built in traceability for utmost integrity

Acquisition modes

Full scan MS

Product ion scan

Precursor ion scan

Constant neutral loss

Multiple reaction monitoring (MRM)

Simultaneous full scan and MRM (RADAR)

RADAR

An information rich acquisition approach that allows you to collect highly specific quantitative data for target compounds while providing the ability to visualize all other components

Mass range

2 to 2048 m/z


比較Xevo TQ系統

比較Xevo TQ系統

Xevo TQ-S cronos

Xevo TQ-S cronos

Xevo TQ-S micro

Xevo TQ-S micro

Xevo TQ-XS

Xevo TQ-XS

Xevo TQ Absolute

Xevo TQ Absolute

尺寸(寬度×高度×深度)

尺寸(寬度×高度×深度)

尺寸(寬度×高度×深度)

尺寸(寬度×高度×深度)

尺寸(寬度×高度×深度)

尺寸(寬度×高度×深度)

35.6 × 60 × 93公分

35.6 × 60 × 93公分

61 × 70.7 × 99.5公分

43 × 79 × 96公分

靈敏度星級

靈敏度星級

靈敏度星級

靈敏度星級

靈敏度星級

靈敏度星級

★★

★★★

★★★★

★★★★★

質量範圍

質量範圍

質量範圍

質量範圍

質量範圍

質量範圍

2~2048 m/z

2~2048 m/z

2~2048 m/z

2~2048 m/z

層析分離配置相容性

層析分離配置相容性

層析分離配置相容性

層析分離配置相容性

層析分離配置相容性

層析分離配置相容性

ACQUITY Arc*

ACQUITY Premier

ACQUITY UPC2*

ACQUITY UPLC

ACQUITY UPLC M-Class*

ACQUITY Premier

ACQUITY UPC2*

ACQUITY UPLC

ACQUITY UPLC M-Class*

APGC*

ACQUITY Premier

ACQUITY UPC2*

ACQUITY UPLC

ACQUITY UPLC M-Class*

APGC*

ACQUITY Premier

ACQUITY UPLC

ACQUITY UPLC M-Class*

APGC*

離子源相容性

離子源相容性

離子源相容性

離子源相容性

離子源相容性

離子源相容性

APCI

ASAP*

ESCi*

ESI

UniSpray

APCI

APGC

ASAP*

ESCi*

ESI

ionKey*

Nanoflow*

UniSpray

APCI

APGC

ASAP*

ESCi*

ESI

ionKey*

Nanoflow*

UniSpray

APCI

APGC

ASAP*

DESI XS*

ESCi*

ESI

Nanoflow

UniSpray

擷取模式

擷取模式

擷取模式

擷取模式

擷取模式

擷取模式

全掃描

子離子掃描

母離子掃描

恆定中性丟失掃描

多重反應監測(MRM)

同時全掃描和MRM (RADAR)

全掃描

子離子掃描

母離子掃描

恆定中性丟失掃描

多重反應監測(MRM)

同時全掃描和MRM (RADAR)

全掃描

子離子掃描

母離子掃描

恆定中性丟失掃描

多重反應監測(MRM)

同時全掃描和MRM (RADAR)

全掃描

子離子掃描

母離子掃描

恆定中性丟失掃描

多重反應監測(MRM)

同時全掃描和MRM (RADAR)

偵測器**

偵測器**

偵測器**

偵測器**

偵測器**

偵測器**

低噪、離軸、長效型光電倍增管**

低噪、離軸、長效型光電倍增管**

低噪、離軸、長效型光電倍增管**

低噪、離軸、長效型光電倍增管**

離子源傳輸元件

離子源傳輸元件

離子源傳輸元件

離子源傳輸元件

離子源傳輸元件

離子源傳輸元件

StepWave

StepWave

StepWave XS

StepWave XS

MRM速度

MRM速度

MRM速度

MRM速度

MRM速度

MRM速度

555 MRM/秒

555 MRM/秒

500 MRM/秒

500 MRM/秒

法規核准***

法規核准***

法規核准***

法規核准***

法規核准***

法規核准***

第三方軟體介面

第三方軟體介面

第三方軟體介面

第三方軟體介面

第三方軟體介面

第三方軟體介面

LIMS介面

MassLynx SkyLine介面

LIMS介面

MassLynx SkyLine介面

LIMS介面

MassLynx SkyLine介面

LIMS介面

MassLynx SkyLine介面

MassLynx Security

MassLynx Security

MassLynx Security

MassLynx Security

MassLynx Security

MassLynx Security

軟體選項

軟體選項

軟體選項

軟體選項

軟體選項

軟體選項

  • MassLynx v4.2
  • waters_connect定量軟體
  • MassLynx v4.2
  • waters_connect定量軟體
  • MassLynx v4.2
  • waters_connect定量軟體
  • MassLynx v4.2
  • waters_connect定量軟體

*不適用於waters_connect

**Waters串聯四極桿質譜儀中每年需要更換偵測器的不到1%。[資料來源:Waters於2006年至2022年間所推出串聯式四極桿質譜儀的維修歷史記錄內部數據]

***法規核准標誌包括CE、CB、NRTL(加拿大/美國)、RCM


Overview

  • Reliable performance: Achieve your objectives in full with operational performance you can rely on.
  • Maximize uptime Get the most from your instrument and avoid time-consuming repair visits.
  • Achieve more with less: Productivity advances to maximize lab capacity. Improve your analytical capabilities and capacity with minimal impact on your coveted bench-space.
  • Optimum productivity with flexible software options: Achieve the ultimate flexibility to choose the right solution for your lab with our flexible software options for quantitation - the waters_connect and MassLynx software platforms.
  • Flexibility to meet your analytical needs: Change the chromatographic inlets or ionization sources to extend your analytical capacity and meet changing demands.

Recommended Use: Laboratory workhorse, offering best value performance per square inch of benchspace with unrivalled flexibility to meet your changing, growing, or unexpected analytical demands.


Features Header

Features Header





Reliable performance

Achieve your objectives in full with operational performance you can rely on. A Xevo TQ-S micro study analyzing mycotoxins in wheat flour (a complex matrix that can contaminate LC-MS instrumentation) showed consistent performance over 5 days of continuous use with 1,000 injections and only 5-9% relative standard deviation (RSD) for peak areas.


Maximize uptime

Get the most from your instrument and avoid time-consuming repair visits. Customers using the Xevo TQ-S micro will on average not need an unplanned service visit during the warranty period and for 3 years after1

Ensure your laboratory runs efficiently and is ready to address the opportunities of tomorrow with Waters comprehensive analytical solutions with expert training (APS) and flexible and cost-effective solutions to advance your business with system service (FlexCHOICE), trade-ins, and technological upgrades (FlexUP)

1Source Waters internal service data on unplanned service visits for Xevo TQ-S micro issues that occur globally. Note that planned visits for regular scheduled Performance Maintenance are recommended to ensure trouble-free operation


Achieve more with less

The Xevo TQ-S micro is 2-3X narrower than other instruments in its class, reducing laboratory space overhead costs. Use of the Xevo TQ-S micro provides up to 34% lower electricity power consumption and associated heat production than other instruments in its class.


Ensure optimum productivity with flexible software options

Achieve the ultimate flexibility to choose the right solution for your lab with our flexible software options for quantitation - the waters_connect and MassLynx software platforms. Our modern, app-based software platform waters_connect delivers efficiency and usability benefits, including the unique Exception Focused Review (XFR) functionality that can save up to 50% of your data review time and ensures your lab is as productive as possible. Meanwhile, our tried, well-established MassLynx Software package delivers superior versatility and flexibility across all application areas.


Flexibility to meet your analytical needs

With the most commonly used atmospheric pressure ionization source of ESI as standard, simply change the chromatographic inlet or ionization source to extend your analytical capacity and meet changing demands.


Resources

Documents

Documents


Support

Support



Related

感受極致的靈敏度、再現性和速度。ACQUITY Premier LC-MS用於分析分離時能發揮一流的靈敏度並呈現出最佳峰型。

利用waters_connect定量分析軟體簡化LC-MS工作流程。這套質譜分析軟體讓實驗室數據管理更容易。

大氣壓GC (APGC)游離源現場升級,讓實驗室擁有可在單MS平台上執行AP GC-MS的能力,從而擴展實驗室LC-MS分析儀器的功能。

食品製造商和檢測實驗室需要與供應商建立靈活的合作夥伴關係,以快速適應新的檢測要求。一直以來,Waters都在為食品檢測實驗室提供技術與服務解決方案,我們因此成為理想的合作夥伴。
回到頁首 回到頁首