This is an Application Brief and does not contain a detailed Experimental section.
This application brief demonstrates fractionation of acidic from base and neutral drugs in urine.
The compounds used in this study are -
| 
                     Column:  | 
                     Symmetry Shield, RP18 4.6 x 100 mm, 3.5 μm  | 
            
| 
                     Guard column:  | 
                     Sentry, 3.9 x 20 mm, 5 μm  | 
            
| 
                     Part numbers:  | 
                     Column- 186000179, Guard- 186000701  | 
            
| 
                     Mobile phase:  | 
                     20 mM KH2PO4/H3PO4, pH 2.7/CH3OH, 52/48 v/v  | 
            
| 
                     Flow rate:  | 
                     2 mL/min  | 
            
| 
                     Injection volume:  | 
                     10 μL of extract with internal standard  | 
            
| 
                     Temperature:  | 
                     30 °C  | 
            
| 
                     Detection:  | 
                     UV @ 214 nm  | 
            
            
        
            
        
            
        WA31764.88, June 2003