This is an Application Brief and does not contain a detailed Experimental section.
This application brief describes the process of monitoring the presence of sulfonamides in milk.
Sulfonamides are widely used for therapeutic and prophylactic purposes in animals. When sulfonamides are retained in food stuff, this may result in allergic or toxic reactions in sensitive consumers. This method can be used to monitor the presence of sulfonamides in milk.
System: |
ACQUITY UPLC System |
Column: |
ACQUITY UPLC BEH C18, 1.7 μm, 2.1 x 100 mm |
Flow rate: |
0.2 mL/min |
Mobile phase A: |
0.05% formic acid/water |
Mobile phase B: |
0.05% formic acid/methanol |
Detector: |
ACQUITY UPLC PDA Detector |
MS System: |
Waters Quattro Premier XE |
Ionization mode: |
Positive electrospray (ESI+) Multiple reaction monitoring |
720002588, April 2008