BioResolve eConnect

Référence du produit : 186009911RF
XSelect Premier Peptide HSS T3 Column, 100Å, 2.5 µm, 4.6 x 100 mm, 1/pk with eConnect Column Tag


Simplifiez votre processus d’achat grâce aux devis personnalisés

Simplifiez votre processus d’achat grâce aux devis personnalisés

Effectuez vos achats sur Waters.com et ajoutez des articles à votre panier

Accéder au panier

Sélectionnez Demander un devis pour obtenir votre devis instantanément


Description du produit

The XSelect Premier Peptide HSS T3 Column, 100Å, 2.5 µm, 4.6 x 100 mm Columns are designed for separations where silica-based selectivities are desired or when increased retention of hydrophilic peptides are required. Each batch of HSS T3, 100A material is QC tested with a gradient separation of a tryptic digest of cytochrome c (p/n: 186006371) and must pass stringent performance criteria before acceptance for use in these columns. This column is part of the MaxPeak Premier class of columns, which deliver the chromatographic performance expected from our particle technologies while increasing reproducibility, peak shape, and recovery for metal-sensitive analytes. Suggested Use: Peptide Separations, Peptide Analysis This column comes equipped with an electronic eConnect column tag containing unique column-specific information. These NFC-enabled device-tagged columns were developed to automatically identify, track and digitally trace column use history. eConnect columns can be used on any HPLC, but its advantages are unlocked when used with the Waters Alliance iS and Alliance iS Bio System running Empower software.

Spécifications

  • Chimie

    C18

  • Mode de séparation

    Phase inverse

  • Particules de support

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    10000 psi (690 Bar)

  • Endcapped

    Oui

  • Technologie de greffage

    T3

  • Silanol Activity

    Medium

  • Particle Shape

    Spherical

  • Granulométrie

    2.5 µm

  • Endfitting Type

    Parker-style

  • Taille des pores

    100 Å

  • Format

    Colonne Premier

  • Superficie

    230

  • Système

    UHPLC, UPLC

  • Technologie de particules

    HSS

  • Technique

    LC

  • Classification USP

    L1

  • Diamètre interne

    4.6 mm

  • Longueur

    100 mm

  • UNSPSC

    41115711

  • Application

    Peptide

  • Gamme

    XSelect

  • Type de produit

    Colonnes

  • Units per Package

    1 pk

  • eConnect

    Yes

Support Produits

Documents