• Application Note

Analysis of Cellulosic Hydrolysates Using ACQUITY UPLC BEH Amide Columns

Analysis of Cellulosic Hydrolysates Using ACQUITY UPLC BEH Amide Columns

  • Waters Corporation

This is an Application Brief and does not contain a detailed Experimental section.

Abstract

This application brief highlights the analysis of cellulosic hydrolysates using ACQUITY UPLC BEH Amide Columns.

Introduction

The compounds analysed in this study are:

  1. Xylose
  2. Fructose
  3. Mannose
  4. Glucose
  5. Sucrose
  6. Cellobiose
  7. Melezitose
  8. Raffinose
  9. Maltotriose
  10. Maltotetraose
  11. Maltopentaose
  12. Maltohexaose
  13. Maltoheptaose
Compounds

Experimental

Chromatographic Conditions

Column:

ACQUITY UPLC BEH Amide 2.1 x 100 mm, 1.7 µm

Part Number:

186004801

Mobile Phase A:

80/20 MeCN/H2O with 0.2% triethylamine [TEA]

Mobile Phase B:

30/70 MeCN/H2O with 0.2% triethylamine [TEA]

Flow Rate:

0.12 mL/min

Gradient:

10 minute gradient, 80%-50% MeCN (w/0.2% TEA) with 30 minute re-equilibration

Injection Volume:

1.3 μL (PLNO)

Sample Concentration:

1 mg/mL each

Sample Diluent:

50/50 MeCN/H2O

Column Temperature:

35 °C

Strong Needle Wash:

20/80 MeCN/H2O (800 μL)

Weak Needle Wash:

75/25 MeCN/H2O (500 μL)

Seal Wash:

50/50 MeCN/H2O

Instrument:

Waters ACQUITY UPLC with ELSD

Gradient

Gradient

ELSD Conditions

Gain:

200

Pressure:

40 psi

Drift Tube Temperature:

40 °C

Nebulizer:

Cooling

Data Rate:

10 pps

Filter Time Constant:

Normal