This is an Application Brief and does not contain a detailed Experimental section.
This application brief highlights analysis of nucleic acid bases
| 
                     Column:  | 
                     Atlantis T3, 4.6 x 150 mm, 5 m  | 
            
| 
                     Part Number:  | 
                     186003747  | 
            
| 
                     Mobile Phase A:  | 
                     H2O  | 
            
| 
                     Mobile Phase B:  | 
                     ACN  | 
            
| 
                     Mobile Phase C:  | 
                     100 mM CH3COONH4, pH 5.0  | 
            
| 
                     Flow Rate:  | 
                     1.0 mL/min  | 
            
| 
                     Injection Volume:  | 
                     10 μL  | 
            
| 
                     Column Temperature:  | 
                     30˚C  | 
            
| 
                     Detection:  | 
                     UV @ 254 nm  | 
            
| 
                     Instrument:  | 
                     Waters Alliance 2695  | 
            
| 
                     Time(min)  | 
                     Profile  | 
            ||
|---|---|---|---|
| 
                     %A  | 
                     %B  | 
                     %C  | 
            |
| 
                     0  | 
                     90  | 
                     0  | 
                     10  | 
            
| 
                     10  | 
                     84  | 
                     6  | 
                     10  | 
            
| 
                     11  | 
                     90  | 
                     0  | 
                     10  | 
            
| 
                     15  | 
                     90  | 
                     0  | 
                     10  | 
            
            
        WA60208, January 2009