Product Listing:  186000440 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg   to   WAS081140 - Analytical Flow Cell

Sorted by Best Sellers
  Product    
info

186000440 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000440

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000440 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000440
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT054275 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: WAT054275

Symmetry columns continues to set the standard for HPLC drug assays, giving you confidence in the long-term compliance of your HPLC methods. No need to compromise on peak shape, selectivity, column-to-column and batch-to-batch reproducibility, or other critical performance characteristics. Available in a variety of particle sizes, chemistries and dimensions.

WAT054275 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: WAT054275
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT045905 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT045905

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT045905 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT045905
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT027324 - µBondapak C18 Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT027324

µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.

WAT027324 - µBondapak C18 Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT027324
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 9.8
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT051910 - Sep-Pak C18 Classic Cartridge, 360 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk

Part Number: WAT051910

Silica-based bonded phase with strong hydrophobicity; used to adsorb analytes of even weak hydrophobicity from aqueous solutions; typical applications include drugs and their metabolites in serum, plasma or urine, desalting of peptides, trace organics in environmental water samples, organic acids in beverages; similar in behavior to reversed-phase HPLC columns.

WAT051910 - Sep-Pak C18 Classic Cartridge, 360 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk
Part Number: WAT051910
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry C18
Endcap End Capped
Format/Type Classic Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 360 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

WAT085188 - Sugar-Pak I Column, 10 µm, 6.5 mm X 300 mm, 1/pkg

Part Number: WAT085188

The Sugar Pak I column separates monosaccharides and sugar alcohols via a strong cation-exchange mechanism. The resin is based on a sulfonated styrene-divinylbenzene polymer that provides pH stability by means of a calcium counterion.

WAT085188 - Sugar-Pak I Column, 10 µm, 6.5 mm X 300 mm, 1/pkg
Part Number: WAT085188
Brand: Sugar-Pak I

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Column
Length (mm) 300 mm
Particle Size (dp) 10 µm
USP Classification L19
Units in Package 1/pkg

info

WAT052880 - AccQ-Fluor Reagent Kit

Part Number: WAT052880

Amino Acid Analysis (AAA) is required for many applications. AccQ-Tag-Fluor Reagent Pkg Includes: AccQTagFluor Reagent 1, 5X 6mL Vials Reagent 2A 5 X 3 mg vials, AccQFluor Reagent 2B 5 X 4mL vials. The components of this kit are not available separately.

WAT052880 - AccQ-Fluor Reagent Kit
Part Number: WAT052880
Brand: AccQ-Tag

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Reagent
Shipping Formulation Liquid & Solid
Storage Room temp
System HPLC -UV

info

WAT045559 - Seal Pack and Needle Replacement Kit

Part Number: WAT045559

The Seal Pack and Needle Replacement Kit contains the following parts: one stainless steel annealed ferrule, one short compression screw (for old style injector only), one needle, one long compression screw (for new style injector only), one seal pak assembly, and the installation instructions.

WAT045559 - Seal Pack and Needle Replacement Kit
Part Number: WAT045559
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Products LC Module 1

info

WAT088122 - Amino Acid Standard (AccQ-Tag, Pico-Tag, Accu-Tag Ultra)

Part Number: WAT088122

Amino Acid Analysis (AAA) is required for many applications. Amino acids are the constituents of proteins and are the intermediates in many metabolic pathways. Qualitative and quantitative AAA is used to determine the concentration of proteins, to identify proteins and to detect structural variants. Contains 10 1mL ampules of amino acid standards for use with AccQTag Ultra, AccQTag, or PICOTag

WAT088122 - Amino Acid Standard (AccQ-Tag, Pico-Tag, Accu-Tag Ultra)
Part Number: WAT088122
Brand: AccQ-Tag

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Frozen -20 C
System HPLC -UV

info

700000254 - PerformancePLUS™Check Valve Cartridges

Part Number: 700000254

The PerformancePLUS™ Check Valve Cartridges are used with pumps that have the PerformancePLUS Cartridge Check Valve System installed. The PerformancePLUS Cartridge Check Valve System can be used as either an inlet or outlet valve in the Waters 1515, 1525, 515, and 600 HPLC pumps, as well as in the LC Module 1 system. The inlet check valves of the 2695, 2695D and the 2795 are also the PerformancePlus type. The check valve materials have been carefully specified for solvent compatibility with all HPLC mobile phases. The housing features a two-piece design that allows it to be removed so that the cartridge can be changed without disturbing the fitting on the housing.

700000254 - PerformancePLUS™Check Valve Cartridges
Part Number: 700000254
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Replacement Schedule Annually

info

201000281 - ACQUITY PDA/TUV 2489/2998 PERFORMANCE MAINTENANCE KIT

Part Number: 201000281

The Waters® Performance Maintenance Kit for the ACQUITY UPLC TUV/PDA contains all of the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. It is used in ACQUITY UPLC PDA Detectors, ACQUITY eLambda PDA Detector, ACQUITY UPLC TUV Detectors, 2489 Dual Wavelength UV Detector and the 2998 PDA Detector. The old part number was 201000186. The Waters® Performance Maintenance Kit includes the following parts: PerformancePLUS™ Long Life Lamp which is warranted for a lifetime of 2000 hours or 1 year, whichever comes first.

201000281 - ACQUITY PDA/TUV 2489/2998 PERFORMANCE MAINTENANCE KIT
Part Number: 201000281
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Replacement Schedule Annually

info

700003114 - Ferrule (PEEK), 1/16, 10/pkg

Part Number: 700003114

Ferrule (PEEK), 1/16, (10PK)

700003114 - Ferrule (PEEK), 1/16, 10/pkg
Part Number: 700003114
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Fittings
Product Category ACQUITY
Replacement Schedule As Needed

info

WAT052890 - AccQ-Tag Eluent A

Part Number: WAT052890

Amino Acid Analysis (AAA) is required for many applications. AccQ-Tag Eluent A Concentrate is available to purchase separetely in a 1 X 1L format.

WAT052890 - AccQ-Tag Eluent A
Part Number: WAT052890
Brand: AccQ-Tag

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Eluent
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

186003539 - ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186003539

The universal, silica-based bonded phase used for the ACQUITY HSS T3 sorbents is compatible with 100% aqueous mobile phase and should be your first choice when developing separations for polar and non-polar compounds. The ACQUITY HSS T3 UPLC columns exhibit ultra-low MS bleed and are fully scalable and transferable to HPLC separations.

186003539 - ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186003539
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UHPLC / UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT086344 - Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT086344

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT086344 - Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT086344
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT066224 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: WAT066224

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT066224 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: WAT066224
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

PSS830115 - Spherisorb Silica Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS830115

The Spherisorb silica chemistry is general purpose unbonded silica substrate designed for normal phase applications.

PSS830115 - Spherisorb Silica Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS830115
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

205000343 - ACQUITY UPLC Col. In-Line Filter Kit

Part Number: 205000343

Waters recommends you filter buffers and samples using a 0.2µm filter prior to using ACQUITY UPLC™ BEH columns. Filtration protects the columns and instrument components from a build-up of particulate matter, improving column lifetime and minimizing system downtime. The ACQUITY UPLC™ column In-line filter kit comes complete with the holder and five 0.2µm stainless steel replacement filters. You can order a a package of five replacement filters using Part Number 700002775 which will work with the in-line filter kit.

205000343 - ACQUITY UPLC Col. In-Line Filter Kit
Part Number: 205000343
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Replacement Schedule As Needed

info

WAT020515 - Sep-Pak C18 Plus Short Cartridge, 360 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk

Part Number: WAT020515

Silica-based bonded phase with strong hydrophobicity; used to adsorb analytes of even weak hydrophobicity from aqueous solutions; typical applications include drugs and their metabolites in serum, plasma or urine, desalting of peptides, trace organics in environmental water samples, organic acids in beverages; similar in behavior to reversed-phase HPLC columns.

WAT020515 - Sep-Pak C18 Plus Short Cartridge, 360 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk
Part Number: WAT020515
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry C18
Endcap End Capped
Format/Type Plus Short Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 360 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

186000442 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000442

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000442 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000442
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186000494 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186000494

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000494 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186000494
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

430001923 - Tubing, HPLC Stainless Steel Inlet

Part Number: 430001923

HPLC Stainless Steel Inlet Tubing, .005ID x 24 long for ACQUITY 30cm Collumn Heater/Cooler

430001923 - Tubing, HPLC Stainless Steel Inlet
Part Number: 430001923
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY UPLC 30cm Column Heater
Replacement Schedule As Needed

info

405000562 - Waters 48-position Vial Holder

Part Number: 405000562

The Waters® 48-position Rectangular Vial-Holder Plate can accomodate either 2mL autosampler vials or 0.65mL microcentrifuge tubes (Eppendorf® style) for use on the 2790/2795 Separations Module. There are two types of 48-position plates: 6 rows x 8 columns and 8 rows by 6 columns.

405000562 - Waters 48-position Vial Holder
Part Number: 405000562
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Separations Module
Replacement Schedule No

info

700002644 - Needle Assembly, PEEK

Part Number: 700002644

ACQUITY SM Needle Assembly, PEEK 30ul, standard

700002644 - Needle Assembly, PEEK
Part Number: 700002644
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Products ACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

205000730 - Active Preheater

Part Number: 205000730

ACQUITY Active Preheater (APH) SS 12.5 inches long

205000730 - Active Preheater
Part Number: 205000730
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Products ACQUITY H-Class Column Heater-Active
Replacement Schedule As Needed

info

186002560 - SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186002560

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002560 - SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186002560
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

PSS830915 - Spherisorb Cyano (CN) Column, Normal Phase, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS830915

The Spherisorb CN chemistry is general purpose normal phase propyl cyano bonded ligand to a silica substrate. This column is conditioned and shipped with normal phase solvent.

PSS830915 - Spherisorb Cyano (CN) Column, Normal Phase, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS830915
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3.1
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

WAT084038 - Carbohydrate Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT084038

The Carbohydrate Analysis Column features a covalently bonded amino packing that is ideally suited for the seperation of low molecular weight sugars such as mono,di-, and trisaccharides. This column typically uses a mobile phase consisting of 65-85% acetonitrile in water and a column temperature ranging from ambient to 35° C.

WAT084038 - Carbohydrate Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT084038
Brand: Carbohydrate

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Amino (NH2)
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
USP Classification L8
Units in Package 1/pkg
pH Range 2 - 8

info

186003117 - XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003117

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003117 - XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003117
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAS081140 - Analytical Flow Cell

Part Number: WAS081140

The Waters®TaperSlit™ Flow Cell design used in the 2487/2489 detectors renders the detector baseline insensitive to change in mobile phase refractive index. Refractive index changes occur during gradient separations or result from temperature or pump-induced pressure fluctuations.The TaperSlit™ flow cell has a taper to the internal bore of the flow cell. In the Waters® Analytical TaperSlit™ FlowCell, the combination of the lens and TaperSlit bore geometry prevents light from hitting the cell walls. The analytical cell has a 10mm path length and a cell volume of 10µL.

WAS081140 - Analytical Flow Cell
Part Number: WAS081140
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors