Product Listing:  186004021 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg   to   186003045 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Sorted by Popularity
  Product    
info

186004021 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186004021

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186004021 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186004021
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186002979 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186002979

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186002979 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186002979
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

176001235 - AccQ-Tag Ultra Chemistry Kit

Part Number: 176001235

Amino Acid Analysis (AAA) is required for many applications. Refill Package. The refill Kit is intended to recharge the AccQTag Ultra chemistries that are a part of the Application Add on kit. This kit should not be purchased as part of an initial system. Includes AccQTag Ultra Deriviativation Kit 250 analyses 186003836, AccQTag Ultra Column 2.1 X 100mm 186003837, AccQTag Eluent A Concentrate (950mL) 186003838, AccQTag Ultra Eluent B (950mL) 186003839, Sample Tubes, 4 X 72pkg WAT007571, Amino Acid Standard, Hydrolyste, 10 X 1mL ampules WAT088122, Tota Recovery Vials, 3 X 100 vial/pkg 186000384C

176001235 - AccQ-Tag Ultra Chemistry Kit
Part Number: 176001235
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Kit
Shipping Formulation Liquid
Storage Refrigerator 2 to 8 C
System UPLC

info

WAT015401 - DeltaPak C18 Radial-Pak Cartridge, 100Å, 15 µm, 47 mm X 300 mm, 1/pkg

Part Number: WAT015401

Delta-Pak packings, ideal for the separation of peptides, proteins, and natural products, are based on a highly stable, bonded, endcapped 5µm or 15µm spherical silica. Delta-Pak is available in two different pore sizes (100Å and 300Å) with either C4 or C18 bonded phase. Delta-Pak packings are available in different cartridge and column configurations, providing consistent and predictable scale-up capabilities for milligram-to-gram scale purification. Also, by having the same chemistry available on a high-efficiency 5µm particle, you can easily check the purity of your fractions.

WAT015401 - DeltaPak C18 Radial-Pak Cartridge, 100Å, 15 µm, 47 mm X 300 mm, 1/pkg
Part Number: WAT015401
Brand: DeltaPak

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Delta-Pak Columns
% Carbon Load 17
Application Peptide
Chemistry C18
Endcapped Yes
Format Radial-Pak Cartridge
ID 47 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 15 µm
Particle Substrate Silica
Pore Size 100Å
Surface Area 300
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186006517 - ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 300Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 186006517

This kit consists of three ACQUITY UPLC BEH300 C18 PST columns packed with three different batches of sorbent.

186006517 - ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 300Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 186006517
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC / UHPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

176001048 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 176001048

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

176001048 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 176001048
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC / UHPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

186004929 - Protein-Pak Hi Res CM, 7µm, 4.6x100 mm, 1/pkg

Part Number: 186004929

Protein-Pak Hi Res Ion-Exchange (IEX) columns were developed to assist in the characterization of recombinant proteins, monoclonal antibodies, and other biological compounds. The non-porous, high compound binding capacity of these particles yields outstanding resolution of charged species in less time compared to use of many traditional porous IEX offerings. In addition, quality control testing with defined protein standards helps ensure consistent batch-to-batch performance.

186004929 - Protein-Pak Hi Res CM, 7µm, 4.6x100 mm, 1/pkg
Part Number: 186004929
Brand: Protein-Pak

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > Protein-Pak Columns
Chemistry Cation-exchange
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 7 µm
Particle Substrate Polymethacrylate
Pore Size Non-porous
Units in Package 1/pkg
pH Range 2 - 11

info

186001831 - Extraction Plate Manifold for Oasis 96-Well Plates

Part Number: 186001831

The Waters manifold for 96-well plates is ideally suited for vacuum extraction of all Waters 96-well plate products including Oasis, Sep-Pak and µElution plates. The manifold kit comes with the Spacer which is required for use with the µElution plates. Collection plates, resovoir trays and sealing caps should be purchased seperately

186001831 - Extraction Plate Manifold for Oasis 96-Well Plates
Part Number: 186001831
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

The Waters manifold for 96-well plates is ideally suited for vacuum extraction of all Waters 96-well plate products including Oasis, Sep-Pak and µElution plates. The manifold kit comes with the Spacer which is required for use with the µElution plates. Collection plates, resovoir trays and sealing caps should be purchased seperately

info

WAT030697 - Shodex KF-801 Column, 6 µm, 8 x 300 mm

Part Number: WAT030697

Ultrahigh efficiency GPC columns

WAT030697 - Shodex KF-801 Column, 6 µm, 8 x 300 mm
Part Number: WAT030697
Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Shodex
Format Column
Length (mm) 300 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Polymer
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info WAT201549 - Insulin HMWP SEC Column, 125Å, 10 µm, 7.8 mm X 300 mm, 5K - 150K, 1/pkg
Part Number: WAT201549
Brand: Insulin HMWP

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations
Chemistry SEC
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode Gel Filtration (aqueous)
Molecular Weight Range 5K - 150K
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
USP Classification L20
Units in Package 1/pkg
pH Range 2 - 8

info

186002122 - RapiGest SF, 50 mg, 1/pk

Part Number: 186002122

RapiGest™ SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants. RapiGest™ SF is available in a variety of formats. This part contains one, 50 mg vial for large scale digestions. Add RapiGest™ SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. US Patent No: 8,580,533

186002122 - RapiGest SF, 50 mg, 1/pk
Part Number: 186002122
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Pharmaceutical and Life Science Standards & Kits > Peptide Standards & Kits > RapiGest SF Surfactant
Applications Life Science
Detector Mass Spec
Product Type Standard
Shipping Formulation Solid
Storage Frozen -20 C
System LC/MS

info

WAT026770 - IC-Pak Anion HC Column, 4.6 x 150 mm

Part Number: WAT026770

Waters offers an array of products for ion chromatography . IC-Pak resin based columns allow you to analyze a full range of ions from numerous sample matrices, both simple and complex. They offer an exceptional linear loading range of less than 1.0 ppb to greater than 400 ppm without dilution and without pH limitation on eluent or sample. The flexibility exists for accurate and reproducible anion and cation analyses at all concentration levels.

WAT026770 - IC-Pak Anion HC Column, 4.6 x 150 mm
Part Number: WAT026770
Brand: IC-Pak HC

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Anion-exchange
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Size (dp) 10 µm
Units in Package 1/pkg

info

WAT026765 - IC-Pak Anion HR Column, 4.6 x 75 mm

Part Number: WAT026765

Waters offers an array of products for ion chromatography . IC-Pak resin based columns allow you to analyze a full range of ions from numerous sample matrices, both simple and complex. They offer an exceptional linear loading range of less than 1.0 ppb to greater than 400 ppm without dilution and without pH limitation on eluent or sample. The flexibility exists for accurate and reproducible anion and cation analyses at all concentration levels.

WAT026765 - IC-Pak Anion HR Column, 4.6 x 75 mm
Part Number: WAT026765
Brand: IC-Pak HR

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Anion-exchange
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Ion-Exchange
Particle Size (dp) 6 µm
Units in Package 1/pkg

info

WAT036570 - IC-Pak Cation M/D Column, 3.9 x 150 mm

Part Number: WAT036570

The silica-based IC-Pak C M/D column allows a simultaneous analysis of monovalent and divalent cations under isocratic conditions. This technology provides the analytical chemist with the most sensitive means of analyzing monovalent cations such as Na+, K+, Li+ and NH4+.

WAT036570 - IC-Pak Cation M/D Column, 3.9 x 150 mm
Part Number: WAT036570
Brand: IC-Pak M/D

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Cation-exchange
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Size (dp) 5 µm
Units in Package 1/pkg

info WAT085188 - Sugar-Pak I Column, 10 µm, 6.5 mm X 300 mm, 1/pkg
Part Number: WAT085188
Brand: Sugar-Pak I

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Column
Length (mm) 300 mm
Particle Size (dp) 10 µm
USP Classification L19
Units in Package 1/pkg

info

WAT010290 - Ion Exclusion Column, 7 µm, 7.8 x 300 mm

Part Number: WAT010290

IC-Pak Ion Exclusion columns are used for the analysis of weak acid anions such as fluoride and short chain organic acids from formate to butyrate.

WAT010290 - Ion Exclusion Column, 7 µm, 7.8 x 300 mm
Part Number: WAT010290
Brand: IC-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Ion Exclusion
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode Ion-Exclusion
Particle Size (dp) 7 µm
Units in Package 1/pkg

info

WAT044234 - Styragel Column, HR 1, 5 µm, 7.8 mm X 300 mm, 100 - 5K, THF , 1/pkg

Part Number: WAT044234

Styragel HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterizing samples in the low to mid molecular range where high resolution is critical.

WAT044234 - Styragel Column, HR 1, 5 µm, 7.8 mm X 300 mm, 100 - 5K, THF , 1/pkg
Part Number: WAT044234
Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 100 - 5K
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Polymer
Pore Size HR 1
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

WAT044231 - Styragel Column, HR 0.5, 5 µm, 7.8 mm X 300 mm, 0 - 1K, THF , 1/pkg

Part Number: WAT044231

Styragel HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterizing samples in the low to mid molecular range where high resolution is critical.

WAT044231 - Styragel Column, HR 0.5, 5 µm, 7.8 mm X 300 mm, 0 - 1K, THF , 1/pkg
Part Number: WAT044231
Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 0 - 1K
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Polymer
Pore Size HR 0.5
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

WAT010295 - Ion Exclusion Column, 7 µm, 7.8 x 150 mm

Part Number: WAT010295

IC-Pak Ion Exclusion columns are used for the analysis of weak acid anions such as fluoride and short chain organic acids from formate to butyrate.

WAT010295 - Ion Exclusion Column, 7 µm, 7.8 x 150 mm
Part Number: WAT010295
Brand: IC-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Ion Exclusion
Format Column
ID 7.8 mm
Length (mm) 150 mm
Mode Ion-Exclusion
Particle Size (dp) 7 µm
Units in Package 1/pkg

info

186002780 - GlycoWorks HILIC uElution Plate

Part Number: 186002780

This plate is ideal for removing contaminants like salts and detergents from hydrophilic analytes, such as carbohydrates, prior to mass spectrometry analysis. It enables elution volumes as low as 25 µL, thereby eliminating time-consuming evaporation steps. The eluted carbohydrates can be analyzed directly by MALDI MS without any prior derivatization. This plate can be used alone for the purpose of extracting carbohydrates, or it can be used as part of our glycan analysis kit (Waters MassPREP Glycoanalysis Kit) to clean up the glycans released from glycoproteins after deglycosylation.

186002780 - GlycoWorks HILIC uElution Plate
Part Number: 186002780
Brand: GlycoWorks

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging 1/pkg
Product Type Kit
Shipping Formulation Solid
Storage Room temp
System LC/MS

info

186006349 - 2-AB Glycan Performance Test Standard

Part Number: 186006349

The 2-AB Glycan Performance Test Standard is 2-AB labeled Human IgG and is QC verified to contain the components needed to benchmark and evaluate ACQUITY UPLC BEH Glycan, 1.7 µm Columns. It comes in a Waters TruView vial as a lyophilized powder. There is 228 pmol total/vial. It is recommended that this standard be used on a regular basis for benchmarking column and system performance, similar to the QCRM product line.

186006349 - 2-AB Glycan Performance Test Standard
Part Number: 186006349
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Packaging 1/pkg
Product Type Column Performances
Shipping Formulation Solid
Storage Frozen -20 C
System UPLC

info

WAT084038 - Carbohydrate Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT084038

The Carbohydrate Analysis Column features a covalently bonded amino packing that is ideally suited for the seperation of low molecular weight sugars such as mono,di-, and trisaccharides. This column typically uses a mobile phase consisting of 65-85% acetonitrile in water and a column temperature ranging from ambient to 35° C.

WAT084038 - Carbohydrate Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT084038
Brand: Carbohydrate

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Amino (NH2)
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
USP Classification L8
Units in Package 1/pkg
pH Range 2 - 8

info

186003687 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186003687

The ACQUITY BEH300 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

186003687 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186003687
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC / UHPLC Columns > ACQUITY UPLC Columns
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Peptide
Silanol Activity Low
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186004742 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186004742

The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.

186004742 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186004742
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC / UHPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186003117 - XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003117

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003117 - XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003117
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003018 - XBridge BEH C8 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003018

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

186003018 - XBridge BEH C8 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003018
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186003010 - XBridge BEH Shield RP18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003010

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003010 - XBridge BEH Shield RP18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003010
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003943 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003943

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003943 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003943
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT034207 - Pullulan Kit

Part Number: WAT034207

A unique collection of GFC standards for molecular weight determination. 8 Pullulan Standards for aqueous MW Testing at 200mg each of approximate molecular weight standards 5000, 10000, 20000, 50000, 100000, 200000, 400000, 800000

WAT034207 - Pullulan Kit
Part Number: WAT034207
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

186003045 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003045

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003045 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003045
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11