Literature


Narrow Results:
Filter list using values below
Description
MassLynx Basic Security - Product Solution
Library Number: LITR135027589 | Format: PDF | File Size: 218.77 kB | Year: 2022 | Content Type: Literature

Using MassLynx Basic Security Software, ensures only trained laboratory staff can access MassLynx functionality based on their assigned role, thereby, aiding laboratory compliance.

MaxPeak Premier Protein SEC Columns Infographic
Library Number: MRKT135092642 | Format: PDF | File Size: 1716.47 kB | Year: 2022 | Content Type: Marketing/Online Tools

This infographic describes about how MaxPeak Premier Columns utilize MaxPeak High Performance Surface, minimize analyte/surface interaction that can lead to sample loss.

BioTech Startup Advances Preclinical Studies for Topical Osteoarthritis Drug with Waters ACQUITY Pre...
Library Number: LITR135092747 | Format: PDF | File Size: 2954.93 kB | Year: 2022 | Content Type: Literature

In this case study we learn how Preclinical Studies can be done for Topical Osteoarthritis Drug with Waters ACQUITY Premier System and Xevo TQ-XS

Waters Columns, Analytical Standards & Reagents Selection Guide Wall Chart
Library Number: MRKT10048737 | Format: PDF | File Size: 936.46 kB | Year: 2022 | Content Type: Marketing/Online Tools

Waters comprehensive family of UPLC, UHPLC, and HPLC Columns offer scientists a diverse range of selectivity and particle size choices that provide exceptional scalability within UPLC, UHPLC, HPLC, and preparative LC applications.

BEH SEC Column Technology Infographic
Library Number: MRKT135040064 | Format: PDF | File Size: 1910.44 kB | Year: 2022 | Content Type: Marketing/Online Tools

Solutions for aggregate analysis and important considerations for SEC Column selection.

MaxPeak Premier Columns with MaxPeak High Performance Surfaces - Ordering Information
Library Number: LITR135082367 | Format: PDF | File Size: 2225.42 kB | Year: 2022 | Content Type: Literature

Waters MaxPeak Premier Columns enable scientists to have more control over their chromatographic separations with the inclusion of MaxPeak High Performance Surfaces (HPS).

LC and LC-MS Chemistry Consumables for Bioseparations - Wall Chart
Library Number: MRKT134669227 | Format: PDF | File Size: 3167.82 kB | Year: 2022 | Content Type: Marketing/Online Tools

LC columns designed and QC tested for analytical separations of amino acids, glycans, oligonucleotides, peptides, and proteins.

The Analysis of Human Haemoglobin Variants Using Mass Spectrometry
Library Number: SCTF135092698 | Format: PDF | File Size: 30720.43 kB | Year: 2021 | Content Type: Scientific Publications

This book is a collation of the studies of Brian Green, OBE, on the analysis of human haemoglobin variants by mass spectrometry from the late 1980’s introduction of electrospray ionization to his retirement in 2018.

Automating Preparation of Matrix-Matched
Library Number: APNT135092651 | Format: Web Page | File Size: - | Year: 2021 | Content Type: Application Notes

This application note demonstrates a method that has been suitable for monitoring compliance with regulatory limits set for AFM1 in milk globally.

The Arc Premier System (BSM-R) as a Flexible LC Platform for Peptide Mapping Assays
Library Number: APNT135092548 | Format: Web Page | File Size: - | Year: 2022 | Content Type: Application Notes

This application brief demonstrates the Arc Premier System featuring the binary solvent manager (BSM-R) is capable of delivering reproducible results across test conditions while minimizing analyte/surface interactions of metal-sensitive analytes.

Analysis and Purification of Synthetic Oligonucleotides, DNA Restriction Fragments, PCR Products and...
Library Number: LITR10010599 | Format: PDF | File Size: 1816.23 kB | Year: 1991 | Content Type: Literature

Analysis and Purification of Synthetic Oligonucleotides, DNA Restriction Fragments, PCR Products and Plasmids by HPLC

Mass Confirmation and Purity Analysis of PCR Primer and Probe Reagents Using High Sensitivity Ion-pa...
Library Number: APNT135092191 | Format: Web Page | File Size: - | Year: 2022 | Content Type: Application Notes

This application note demonstrates the use of optimized IP-RPLC and a compliance-ready benchtop Tof instrument for the quality assessment of PCR test reagents used in the SARS-CoV-2 CDC assay.

BioAccord Academia Infographic
Library Number: MRKT135092125 | Format: PDF | File Size: 2770.99 kB | Year: 2022 | Content Type: Marketing/Online Tools

This infographic demonstrates that, the BioAccord system can answer your scientific questions quickly, easily, and without LC-MS experience.

The Benefits of waters_connect MRM Processing Application, MS Quan
Library Number: LITR135092021 | Format: PDF | File Size: 1692.25 kB | Year: 2021 | Content Type: Literature

The objective of this white paper is to discuss the data processing app called MS Quan that will deliver the ability to quantify and report data on the waters_connect platform for Waters tandem quadrupole mass spectrometer-based LC-MS systems.

Automated Method Development Using Analytical Quality-by-Design for Stability Indicating Methods
Library Number: APNT135091884 | Format: Web Page | File Size: - | Year: 2021 | Content Type: Application Notes

This application note demonstrates, the development of a stability indicating method used to monitor Tenofovir alafenamide fumarate drug substance after exposure to forced degradation conditions. An automated, statistical approach was employed by utilizin...

Development of a Multiproduct Method for Analysis of Cholesterol-Lowering Drugs by UltraPerformance ...
Library Number: APNT135091807 | Format: Web Page | File Size: - | Year: 2021 | Content Type: Application Notes

This application note demonstrates the steps of a method development based on design of experiments approach using the ACQUITY UltraPerformance Convergence Chromatography (UPC²) System. The studied compounds belong to statin class, used for lowering high ...

Instrument Considerations for Successful Adaptation of Amino Acid Analysis Methods which Utilize Pre...
Library Number: APNT135091809 | Format: Web Page | File Size: - | Year: 2021 | Content Type: Application Notes

This application note demonstrates the Amino acid analysis (AAA) by high-performance liquid chromatography has its own unique challenges due to the chemical and physical properties of the analytes.

Authentication of Cocoa Butter by Direct Analysis using RADIAN ASAP with LiveID
Library Number: APNT135091796 | Format: Web Page | File Size: - | Year: 2021 | Content Type: Application Notes

This application brief demonstrates the use of RADIAN ASAP with LiveID to swiftly identify adulterated cocoa butter. LiveID enabled us to transform complex raw MS data into simple-to-interpret chemometric models.

Comparable Chromatographic Performance for Amino Acid Analysis Using the AccQ•Tag Ultra VanGuard Pre...
Library Number: APNT135091783 | Format: Web Page | File Size: - | Year: 2021 | Content Type: Application Notes

This application note demonstrates the analysis of complex matrices can cause column performance issues when performed routinely.

Instrument Considerations for Successful Adaptation of Amino Acid Analysis Methods Which Utilize Pre...
Library Number: APNT135091786 | Format: Web Page | File Size: - | Year: 2021 | Content Type: Application Notes

This application note demonstrates the original ACQUITY UPLC methods developed for amino acid analysis have been successfully adapted for the ACQUITY UPLC H-Class PLUS Binary System with no loss of performance.

Analysis of Aminoglycosides in Foods Using a Zwitterionic Stationary Phase and Liquid Chromatography...
Library Number: APNT135091778 | Format: PDF | File Size: 1861.39 kB | Year: 2021 | Content Type: Application Notes

This application note demonstrates about HILIC-MS/MS method which provides a good solution for the screening and quantification of AMGs in foods.

HILIC as an Alternative Separation Mode for Intact Mass Confirmation of Oligonucleotides on the BioA...
Library Number: APNT135090878 | Format: PDF | File Size: 1029.14 kB | Year: 2021 | Content Type: Application Notes

This application note demonstrates about the BioAccord LC-MS System, which enables waters_connect users to perform rapid and accurate intact mass confirmations for small and medium size oligonucleotides (up to 50-mers).

Waters Premier Standards to Investigate the Inertness of Chromatographic Surfaces
Library Number: APNT135080186 | Format: PDF | File Size: 433.54 kB | Year: 2021 | Content Type: Application Notes

This application note demonstrates the ability to assess the inertness of the recently introduced ACQUITY Premier System, which has been designed to eliminate metal-analyte secondary interaction.

Improving Recovery and Quantitation of Oligonucleotide Impurities Using MaxPeak HPS Technology
Library Number: APNT135083281 | Format: PDF | File Size: 653.81 kB | Year: 2021 | Content Type: Application Notes

ACQUITY Premier Columns and LC systems were designed with MaxPeak High Performance Surfaces Technology to address the variability in the analysis of metal-sensitive analytes such as oligonucleotides. The ACQUITY Premier Solution offers out-of-the-box perf...

Trace Level Analysis of Per- And Polyfluoroalkyl Substances (PFAS) In Solid Cosmetics Following A Me...
Library Number: PSTR135091692 | Format: PDF | File Size: 758.76 kB | Year: 2021 | Content Type: Posters

This poster presented at virtual PFAS conference from December 6-10 for the 2021,held at Michigan.