Xbridge Shield RP18 Columns

XBridge Shield RP18 Columns
SKU: 186002990
List Price
8,454.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186002990
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    OBD Prep Column

  • Inner Diameter

    30 mm

  • Length

    150 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186002989
List Price
5,645.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186002989
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    OBD Prep Column

  • Inner Diameter

    30 mm

  • Length

    100 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186007808
List Price
439.00 USD
Category: Columns
XBridge BEH Sheild RP18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XBridge BEH Sheild RP18 analytical columns containing 2.5 µm sorbent particles.
Part Number: 186007808
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Guards

  • Units per Package

    3 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Parker-style

  • Format

    XP VanGuard Cartridge

  • Inner Diameter

    2.1 mm

  • Length

    5 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    2.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

SKU: 186003042
List Price
730.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003042
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    Column

  • Inner Diameter

    4.6 mm

  • Length

    50 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186003150
List Price
999.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003150
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    Column

  • Inner Diameter

    1 mm

  • Length

    150 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 176002564
List Price
2,479.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
Part Number: 176002564
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    3 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Parker-style

  • Format

    XP Column

  • Inner Diameter

    2.1 mm

  • Length

    75 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    2.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • eCord

    Yes

SKU: 186006058
List Price
918.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
Part Number: 186006058
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Parker-style

  • Format

    XP Column

  • Inner Diameter

    3 mm

  • Length

    75 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    2.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • eCord

    Yes

SKU: 186007810
List Price
439.00 USD
Category: Columns
XBridge BEH Sheild RP18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XBridge BEH Sheild RP18 analytical columns containing 2.5 µm sorbent particles.
Part Number: 186007810
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Guards

  • Units per Package

    3 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Parker-style

  • Format

    XP VanGuard Cartridge

  • Inner Diameter

    3.9 mm

  • Length

    5 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    2.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

SKU: 186002986
List Price
2,856.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186002986
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    OBD Prep Column

  • Inner Diameter

    19 mm

  • Length

    100 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186008171
List Price
2,096.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186008171
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    OBD Prep Column

  • Inner Diameter

    10 mm

  • Length

    250 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186004965
List Price
1,937.00 USD
Category: Columns
Method transfer kits are designed to preserve the integrity of a separation as it is transferred between UPLC and HPLC platforms. Based on the concept of maintaining column length [L] to particle size [dp] ratio [L/dp], these kits provide an ACQUITY UPLC column with an HPLC column of equivalent selectivity and resolving power. Using the ACQUITY UPLC columns calculator, methods can be fully transferred from HPLC to UPLC or from UPLC to HPLC.
Part Number: 186004965
  • UNSPSC

    41115709

  • Brand

    ACQUITY UPLC, XBridge

  • Product Type

    Column Kits

  • Units per Package

    2 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Method Transfer Kit

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    1.7 - 3.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Surface Area

    185

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

SKU: 176002568
List Price
2,479.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
Part Number: 176002568
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    3 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Parker-style

  • Format

    XP Column

  • Inner Diameter

    3 mm

  • Length

    75 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    2.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • eCord

    Yes

SKU: 186003071
List Price
356.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003071
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Guards

  • Units per Package

    2 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Sentry Guard Cartridge

  • Inner Diameter

    2.1 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186003998
List Price
7,840.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003998
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    OBD Prep Column

  • Inner Diameter

    50 mm

  • Length

    50 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    10 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186003159
List Price
677.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003159
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    Intelligent Speed (IS) Column

  • Inner Diameter

    3 mm

  • Length

    30 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186003792
List Price
2,995.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003792
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Column Kits

  • Units per Package

    3 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    Method Validation Kit

  • Inner Diameter

    4.6 mm

  • Length

    150 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186006052
List Price
863.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
Part Number: 186006052
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Parker-style

  • Format

    XP Column

  • Inner Diameter

    2.1 mm

  • Length

    30 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    2.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • eCord

    Yes

SKU: 186006060
List Price
863.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
Part Number: 186006060
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Parker-style

  • Format

    XP Column

  • Inner Diameter

    4.6 mm

  • Length

    30 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    2.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    10000 psi (690 Bar)

SKU: 186003007
List Price
762.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003007
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    Column

  • Inner Diameter

    4.6 mm

  • Length

    75 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186003009
List Price
971.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003009
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    Column

  • Inner Diameter

    4.6 mm

  • Length

    150 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186003996
List Price
8,454.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003996
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    OBD Prep Column

  • Inner Diameter

    30 mm

  • Length

    150 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    10 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186006763
List Price
3,211.00 USD
Category: Columns
This method validation kit consists of three XBridge BEH Shield RP18 columns packed with three different batches of sorbent. XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
Part Number: 186006763
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Column Kits

  • Units per Package

    3 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    Method Validation Kit

  • Inner Diameter

    2.1 mm

  • Length

    150 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    2.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

SKU: 186003993
List Price
2,856.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003993
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    OBD Prep Column

  • Inner Diameter

    19 mm

  • Length

    100 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    10 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186008213
List Price
1,784.00 USD
Category: Columns
XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186008213
  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

  • Carbon Load

    17 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Waters

  • Format

    OBD Prep Column

  • Inner Diameter

    10 mm

  • Length

    150 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    10 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    BEH

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    50 C (low pH)/45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

Related Categories

Back To Top Back To Top