Symmetry C18 Columns

Symmetry C18 Columns
SKU: WAT200632
Category: Columns
Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.
Part Number: WAT200632
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    100 Å

  • Format

    Column

  • Surface Area

    335

  • System

    HPLC

  • USP Classification

    L1

  • Inner Diameter

    4.6 mm

  • Length

    150 mm

  • Carbon Load

    19 %

  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: WAT046980
Category: Columns
Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.
Part Number: WAT046980
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    100 Å

  • Format

    Column

  • Surface Area

    335

  • System

    HPLC

  • USP Classification

    L1

  • Inner Diameter

    3.9 mm

  • Length

    150 mm

  • Carbon Load

    19 %

  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Columns

  • Units per Package

    1 pk

SKU: WAT045905
Category: Columns
Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.
Part Number: WAT045905
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    100 Å

  • Format

    Column

  • Surface Area

    335

  • System

    HPLC

  • USP Classification

    L1

  • Inner Diameter

    4.6 mm

  • Length

    150 mm

  • Carbon Load

    19 %

  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Columns

  • Units per Package

    1 pk

Symmetry C18 Column
SKU: WAT066224
Category: Columns
Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.
Part Number: WAT066224
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    100 Å

  • Format

    Column

  • Surface Area

    335

  • System

    HPLC

  • USP Classification

    L1

  • Inner Diameter

    4.6 mm

  • Length

    75 mm

  • Carbon Load

    19 %

  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Columns

  • Units per Package

    1 pk

Prep Guard Cartridge 19 mm x 10 mm
SKU: 186001835
Category: Columns
These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP18 column significantly improves peak shape and resolution. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information
Part Number: 186001835
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Temperature Limits

    45 C

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Pore Size

    100 Å

  • Format

    Prep Guard Cartridge

  • Surface Area

    335

  • System

    HPLC Preparative

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    19 mm

  • Length

    10 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Guards

  • Units per Package

    1 pk

SKU: 186001836
Category: Columns
These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP18 column significantly improves peak shape and resolution.
Part Number: 186001836
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Temperature Limits

    45 C

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    100 Å

  • Format

    Prep Column

  • Surface Area

    335

  • System

    HPLC Preparative

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    19 mm

  • Length

    50 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

SKU: 186001837
Category: Columns
These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP18 column significantly improves peak shape and resolution.
Part Number: 186001837
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Temperature Limits

    45 C

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    100 Å

  • Format

    Prep Column

  • Surface Area

    335

  • System

    HPLC Preparative

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    19 mm

  • Length

    100 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

SKU: 186001838
Category: Columns
These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP18 column significantly improves peak shape and resolution.
Part Number: 186001838
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Temperature Limits

    45 C

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    100 Å

  • Format

    Prep Column

  • Surface Area

    335

  • System

    HPLC Preparative

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    19 mm

  • Length

    150 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

SKU: 186001839
Category: Columns
These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP18 column significantly improves peak shape and resolution.
Part Number: 186001839
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Temperature Limits

    45 C

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    7 µm

  • Endfitting Type

    Waters

  • Pore Size

    100 Å

  • Format

    Prep Column

  • Surface Area

    335

  • System

    HPLC Preparative

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    19 mm

  • Length

    150 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

SKU: 186001850
Category: Columns
Symmetry columns continues to set the standard for HPLC drug assays, giving you confidence in the long-term compliance of your HPLC methods. No need to compromise on peak shape, selectivity, column-to-column and batch-to-batch reproducibility, or other critical performance characteristics. Available in a variety of particle sizes, chemistries and dimensions.
Part Number: 186001850
  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Temperature Limits

    45 C

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    300 Å

  • Format

    Prep Column

  • Surface Area

    110

  • System

    HPLC Preparative

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    19 mm

  • Length

    150 mm

  • Carbon Load

    8.5 %

  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Preparative Columns

  • Units per Package

    1 pk

Related Categories