ACQUITY and XBridge Premier Oligonucleotide BEH C18 300 Å Columns deliver high resolution long-mer separations with UHPLC compatible separations.

SKU: 186010729
XSelect Premier Peptide HSS T3 Column, 100 Å, 2.5 µm, 4.6 x 150 mm with Premier VanGuard FIT Guard, 1/pk


Semplifica gli acquisti con preventivi personalizzati

Semplifica gli acquisti con preventivi personalizzati

Acquista su Waters.com e aggiungi articoli al carrello

Seleziona Richiedi un Preventivo per ottenere immediatamente il preventivo


Descrizione del Prodotto

The XSelect Premier Peptide HSS T3 Column, 100 Å, 2.5 µm, 4.6 mm X 150 mm with Premier VanGuard FIT Guard Columns are designed for separations where silica-based selectivities are desired or when increased retention of hydrophilic peptides are required. Each batch of HSS T3, 100Å material is QC tested with a gradient separation of a tryptic digest of cytochrome c (p/n: 186006371) and must pass stringent performance criteria before acceptance for use in these columns. This column is part of the MaxPeak Premier class of columns, which deliver the chromatographic performance expected from our particle technologies while increasing reproducibility, peak shape, and recovery for metal-sensitive analytes. The unique column design includes a fully integrated and easily replaceable 5mm pre-column that serves to protect and extend the life of the full-length analytical column, but adds no dispersion and has no impact on the resolution of your analytical separations. VanGuard FIT Cartridge replacements contain the same qualified sorbent as the analytical column and can easily be replaced.

Suggested Use: Peptide Separations, Peptide Analysis

Specifiche

  • Chimica

    C18

  • Modalità di separazione

    Fase inversa

  • Substrato particellare

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Temperature Limits

    45 C

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

  • Tecnologia dei legami

    T3

  • Silanol Activity

    Medium

  • Particle Shape

    Spherical

  • Diametro delle particelle

    2.5 µm

  • Endfitting Type

    Parker-style

  • Dimensioni dei pori

    100 Å

  • QC Tested

    Peptide

  • Formato

    Colonna PREMIER

  • Packing Solvent

    Acetonitrile

  • Superficie

    230

  • Sistema

    UHPLC, UPLC

  • Tecnologia delle particelle

    HSS

  • Technique

    LC

  • Classificazione USP

    L1

  • Diametro interno

    4.6 mm

  • Lunghezza

    150 mm

  • Carbon Load

    11 %

  • eCord

    No

  • UNSPSC

    41115711

  • Applicazione

    Peptidi

  • Marchio

    XSelect

  • Units per Package

    1 pk

Supporto Prodotti

Documenti

Documenti



Prodotti correlati

Torna all'inizio Torna all'inizio