SKU: 186010688
XBridge PREMIER Oligonucleotide BEH C18 Column, 130 Å, 2.5 µm, 2.1 mm X 50 mm with Premier VanGuard FIT Guard, 1/pk


Semplifica gli acquisti con preventivi personalizzati

Semplifica gli acquisti con preventivi personalizzati

Acquista su Waters.com e aggiungi articoli al carrello

Seleziona Richiedi un Preventivo per ottenere immediatamente il preventivo


Descrizione del Prodotto

XBridge Premier Oligonucleotide BEH C18 Column, 130 Å, 2.5 µm, 2.1 mm X 50 mm with Premier VanGuard FIT Guard, 1/pk are used to separate synthetic oligonucleotides based on ion-pairing reversed-phase (IP-RP) chromatography. Each column is QC tested using Waters MassPrep OST standards to ensure repeatable performance. This column is part of the MaxPeak Premier line of columns, which deliver an ultra-low non-adsorptive surface that maximizes sensitivity and reproducibility when separating metal-sensitive analytes, such as oligonucleotides. The unique column design includes a fully integrated and easily replaceable 5mm pre-column that serves to protect and extend the life of the full-length analytical column, but adds no dispersion and has no impact on the resolution of your analytical separations. VanGuard FIT Cartridge replacements contain the same qualified sorbent as the analytical column and can easily be replaced.

Waters has removed paper COAs and eCords from select columns for easy access with less waste. All column documents are now available at www.waters.com/coa

Specifiche

  • Chimica

    C18

  • Modalità di separazione

    Fase inversa

  • Substrato particellare

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

  • Tecnologia dei legami

    dC18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Diametro delle particelle

    2.5 µm

  • Endfitting Type

    Parker-style

  • Dimensioni dei pori

    130 Å

  • QC Tested

    Oligonucleotide

  • Formato

    Colonna PREMIER

  • Packing Solvent

    Acetonitrile

  • Superficie

    185

  • Sistema

    UHPLC, UPLC

  • Tecnologia delle particelle

    BEH

  • Technique

    LC

  • Classificazione USP

    L1

  • Diametro interno

    2.1 mm

  • Lunghezza

    50 mm

  • Carbon Load

    18 %

  • UNSPSC

    41115709

  • Applicazione

    Oligonucleotidi

  • Marchio

    XBridge

  • Tipo di prodotto

    Colonne

  • Units per Package

    1 pk