{"id":7176,"date":"2026-11-17T14:06:44","date_gmt":"2026-11-17T14:06:44","guid":{"rendered":"https:\/\/www.waters.com\/blog\/?p=7176"},"modified":"2026-11-17T14:06:45","modified_gmt":"2026-11-17T14:06:45","slug":"the-monoclonal-antibody-aggregate-was-never-just-one-aggregate","status":"publish","type":"post","link":"https:\/\/www.waters.com\/blog\/the-monoclonal-antibody-aggregate-was-never-just-one-aggregate\/","title":{"rendered":"The Monoclonal Antibody Aggregate Was Never Just One Aggregate"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">A high-molecular-weight (HMW) aggregate peak often appears as a single population. But what if it isn&#8217;t?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/doi.org\/10.64898\/2026.10.08.757778\">In a recent <em>bioRxiv<\/em> preprint<\/a>, scientists from WuXi Biologics, Zhejiang University (China), and Waters Corporation used charge detection mass spectrometry (CDMS) to take a closer look at a complex antibody aggregate fraction. What appeared to be one broad aggregate population was actually composed of <strong>17 distinct ion families ranging from about 300 kDa to nearly 2 MDa<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For biopharmaceutical scientists, that distinction matters. Process changes, formulation decisions, stability assessments, and product quality evaluations all depend on understanding exactly which species are present, not simply the average molecular weight of the population.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This study shows how CDMS moves beyond aggregate detection to reveal aggregate composition.<\/p>\n\n\n\n<ul class=\"wp-block-list has-theme-palette-9-color has-theme-palette-1-background-color has-text-color has-background has-link-color wp-elements-1\">\n<li><strong>Commercial CDMS is ready for antibody analysis:<\/strong> The team benchmarked the Waters Xevo CDMS and showed reproducible, robust mass and charge measurements under antibody-relevant conditions, with a molar response that supports semi-quantitative estimates of relative abundance.<\/li>\n\n\n\n<li><strong>CDMS reveals what other methods average away:<\/strong> Applied to heat-stressed trastuzumab, CDMS resolved 17 ion families within a high-molecular-weight fraction that SEC-MALS reported as a single average and native MS could not deconvolute.<\/li>\n<\/ul>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-7176_56defd-2c .kt-block-spacer{height:60px;}.wp-block-kadence-spacer.kt-block-spacer-7176_56defd-2c .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-7176_56defd-2c\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\"\/><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">The challenge: Measuring each species, not the average<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Monomers and dimers are well served by established methods. Higher-order aggregates are harder. They are low in abundance, highly heterogeneous, and become more so as they grow. The need is to measure each species within that population, rather than one value for all of it.&nbsp; Orthogonal methods each contribute something different:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>SEC-MALS<\/strong> excels at determining absolute average molecular weights and aggregate distributions but reports co-eluting species as a single average.<\/li>\n\n\n\n<li><strong>Mass photometry<\/strong> offers rapid, low-volume single-particle measurements, but its dynamic range cannot readily be tuned toward rare, high-mass species.<\/li>\n\n\n\n<li><strong>Native mass spectrometry<\/strong> provides molecular mass information under non-denaturing conditions, but for highly heterogeneous, megadalton-scale assemblies, overlapping charge-state distributions make deconvolution extremely difficult, leaving complex aggregates as broad, unresolved signals.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Each method confirms that HMW species are present. The open question is what they are.<\/p>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-7176_59a715-23 .kt-block-spacer{height:60px;}.wp-block-kadence-spacer.kt-block-spacer-7176_59a715-23 .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-7176_59a715-23\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\"\/><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">How CDMS fills the gap<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">CDMS measures the mass-to-charge ratio (<em>m\/z<\/em>) and the charge of each ion independently, then multiplies them to obtain the ion\u2019s mass. Because charge is measured, not <a>inferred,<\/a> mass can be determined even when charge states aren\u2019t resolved, solving the problem that limits conventional native MS for heterogeneous assemblies.<\/p>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-7176_22959a-36 .kt-block-spacer{height:60px;}.wp-block-kadence-spacer.kt-block-spacer-7176_22959a-36 .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-7176_22959a-36\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\"\/><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Key point 1: Benchmarking commercial CDMS for antibodies<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The researchers first established that the commercial <a href=\"https:\/\/www.waters.com\/nextgen\/global\/products\/mass-spectrometry\/mass-spectrometry-systems\/charge-detection-mass-spectrometry.html\">Xevo CDMS<\/a> delivers the analytical performance antibody work demands:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Reproducible measurements &#8211;<\/strong> Repeatability and intermediate-precision RSDs below 1% for both mass and charge.<\/li>\n\n\n\n<li><strong>Robust mass measurement &#8211;<\/strong> Measured mass stayed consistent across the concentrations, pH values and buffers tested. These variables shifted charge and ion signal more than mass.<\/li>\n\n\n\n<li><strong>Semi-quantitative response &#8211;<\/strong> Predefined molar ratios of two antibody-derived species, from 10:1 to 1:4, were reproduced with R\u00b2 &gt;0.99 and a slope of 1.003. Because CDMS counts individual ions, its response reflects molar abundance rather than the mass-weighted signal of methods such as SEC-UV.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-theme-palette-9-color has-theme-palette-1-background-color has-text-color has-background has-link-color has-fixed-layout\"><tbody><tr><td><strong>Sample requirement:<\/strong> Concentrations of 0.005\u20130.01 mg\/mL (33\u201367 nM) gave reproducible single-ion distributions, roughly 1000- to 2000-fold lower than the 67 \u00b5M used for SEC.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-7176_c56d7d-70 .kt-block-spacer{height:60px;}.wp-block-kadence-spacer.kt-block-spacer-7176_c56d7d-70 .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-7176_c56d7d-70\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\"\/><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Key point 2: One aggregate fraction, 17 species<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The team heat-stressed trastuzumab and separated its HMW aggregates into fractions. In the most complex of these, fraction H1, orthogonal methods confirmed that HMW species were present but could not resolve what they were.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">CDMS told a different story. Plotting each ion\u2019s mass against its charge separated 17 ion families\u2014from about 302 kDa to 1.95 MDa. The populations became distinguishable only when mass and charge were considered together. Three findings follow:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Discrete populations, not a continuum &#8211;<\/strong> What looked like a single heterogeneous aggregate was a set of discrete assemblies, each resolvable in its own right.<\/li>\n\n\n\n<li><strong>Recurring building blocks &#8211;<\/strong> Recurring mass offsets of about 25 and 50 kDa indicate that the aggregates are built from intact antibodies combined in varying ways with chain-derived components, including light chains, light-chain dimers and light-chain\/heavy-chain species. The study did not assign each population to a unique structure, but the mass pattern exposes how the species relate to one another.<\/li>\n\n\n\n<li><strong>Charge as a second dimension &#8211;<\/strong> Charge carried information that mass alone did not. Two families near 612 and 673 kDa carried about 6% more and 7% less charge than expected for their mass, pointing to differences in conformation or composition between them.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Together, these findings change the question from \u201cHow much aggregate is present?\u201d to \u201cWhich aggregate species are present, and how are they related?\u201d<\/p>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-7176_80f5ab-41 .kt-block-spacer{height:60px;}.wp-block-kadence-spacer.kt-block-spacer-7176_80f5ab-41 .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-7176_80f5ab-41\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\"\/><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Key takeaway<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Antibody aggregates are rarely one thing. An average molar mass is the right number for quantitation, but it leaves the composition of a heterogeneous fraction open. In this study, CDMS on a commercial instrument resolved 17 populations within a single fraction, related them through recurring building blocks, and used charge to flag differences that mass alone did not show.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For teams developing therapeutic antibodies, CDMS adds a compositional layer alongside SEC-MALS and other orthogonal methods\u2014a way to see what\u2019s inside the aggregate fraction when stability, formulation or process decisions depend on it.<\/p>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-7176_0e8c4c-46 .kt-block-spacer{height:60px;}.wp-block-kadence-spacer.kt-block-spacer-7176_0e8c4c-46 .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-7176_0e8c4c-46\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\"\/><\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/doi.org\/10.64898\/2026.10.08.757778\"><strong>Read the full study,<\/strong><\/a> <strong>\u201c<\/strong>Benchmarking the Performance of a Commercial Electrostatic Linear Ion Trap (ELIT) Charge Detection Mass Spectrometer for Higher-Order Antibody Aggregate Analysis\u201d, Shang-Yin Wu, Xing-Miao Guo, Jia-Yi Lv, et al.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>This preprint has not yet been peer reviewed. Waters scientists are co-authors of the study.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A high-molecular-weight (HMW) aggregate peak often appears as a single population. But what if it isn&#8217;t? In a recent bioRxiv preprint, scientists from WuXi Biologics, Zhejiang University (China), and Waters Corporation used charge detection mass spectrometry (CDMS) to take a closer look at a complex antibody aggregate fraction. What appeared to be one broad aggregate&#8230;<\/p>\n","protected":false},"author":165,"featured_media":7177,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[22],"tags":[781,705,64,24,788],"class_list":["post-7176","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technology","tag-cdms","tag-charge-detection-mass-spectrometry","tag-lc-ms","tag-mass-spectrometry-ms","tag-xevo-cdms"],"acf":[],"taxonomy_info":{"category":[{"value":22,"label":"Technology"}],"post_tag":[{"value":781,"label":"CDMS"},{"value":705,"label":"charge detection mass spectrometry"},{"value":64,"label":"LC-MS"},{"value":24,"label":"mass spectrometry (MS)"},{"value":788,"label":"xevo cdms"}]},"featured_image_src_large":["https:\/\/www.waters.com\/blog\/wp-content\/uploads\/adobestock_895128153_small-800px-standard-background.jpg",600,337,false],"author_info":{"display_name":"Kate Yu","author_link":"https:\/\/www.waters.com\/blog\/author\/kyu\/"},"comment_info":"","category_info":[{"term_id":22,"name":"Technology","slug":"technology","term_group":0,"term_taxonomy_id":22,"taxonomy":"category","description":"Our expertise drives innovation, development, and\u00a0application of informatics and software that continue to enable leading pharmaceutical, environmental, food &amp; beverage and chemical materials organizations to accelerate decision-making, improve laboratory effectiveness, and get products to market faster.","parent":0,"count":132,"filter":"raw","term_order":"0","cat_ID":22,"category_count":132,"category_description":"Our expertise drives innovation, development, and\u00a0application of informatics and software that continue to enable leading pharmaceutical, environmental, food &amp; beverage and chemical materials organizations to accelerate decision-making, improve laboratory effectiveness, and get products to market faster.","cat_name":"Technology","category_nicename":"technology","category_parent":0}],"tag_info":[{"term_id":781,"name":"CDMS","slug":"cdms","term_group":0,"term_taxonomy_id":781,"taxonomy":"post_tag","description":"","parent":0,"count":9,"filter":"raw","term_order":"0"},{"term_id":705,"name":"charge detection mass spectrometry","slug":"charge-detection-mass-spectrometry","term_group":0,"term_taxonomy_id":705,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","term_order":"0"},{"term_id":64,"name":"LC-MS","slug":"lc-ms","term_group":0,"term_taxonomy_id":64,"taxonomy":"post_tag","description":"","parent":0,"count":40,"filter":"raw","term_order":"0"},{"term_id":24,"name":"mass spectrometry (MS)","slug":"mass-spectrometry-ms","term_group":0,"term_taxonomy_id":24,"taxonomy":"post_tag","description":"","parent":0,"count":71,"filter":"raw","term_order":"0"},{"term_id":788,"name":"xevo cdms","slug":"xevo-cdms","term_group":0,"term_taxonomy_id":788,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","term_order":"0"}],"_links":{"self":[{"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/posts\/7176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/users\/165"}],"replies":[{"embeddable":true,"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/comments?post=7176"}],"version-history":[{"count":3,"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/posts\/7176\/revisions"}],"predecessor-version":[{"id":7188,"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/posts\/7176\/revisions\/7188"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/media\/7177"}],"wp:attachment":[{"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/media?parent=7176"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/categories?post=7176"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/tags?post=7176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}