{"id":4431,"date":"2016-03-08T18:18:00","date_gmt":"2016-03-08T18:18:00","guid":{"rendered":"https:\/\/www.waters.com\/blog\/acquity-arc-system-transferring-validated-hplc-methods-within-usp-guidelines\/"},"modified":"2023-07-06T14:35:56","modified_gmt":"2023-07-06T14:35:56","slug":"acquity-arc-system-transferring-validated-hplc-methods-within-usp-guidelines","status":"publish","type":"post","link":"https:\/\/www.waters.com\/blog\/acquity-arc-system-transferring-validated-hplc-methods-within-usp-guidelines\/","title":{"rendered":"ACQUITY Arc System: Transferring Validated HPLC Methods within USP Guidelines"},"content":{"rendered":"<p>The thought of transferring established high performance liquid chromatography (HPLC) methods onto a another vendor\u2019s LC, or a new platform like UHPLC\/UPLC, may cause a bit of anxiety for those that may be unaware of how easy it can be.<\/p>\n<p>The reason that the topic of analytical method transfer induces so much angst is that for the transfer of an LC method to succeed, the method has to work as well on the new system it is being transferred to as it did on the original system it was developed on. Additionally, regulators want documented proof that the transfer was completed successfully by demonstrating competency and analytical verification of equivalence (at the very least), or a complete re-validation for the very risk verse. This isn\u2019t always perceived as a straightforward process.<\/p>\n<p>Here is where the ACQUITY<sup>\u00ae<\/sup> Arc System from Waters can help.<\/p>\n<p>The <a href=\"https:\/\/www.waters.com\/waters\/nav.htm?cid=134844390\" target=\"_blank\" rel=\"noopener\">ACQUITY Arc System<\/a>, enabled by Arc Multi-Flow path\u2122 technology, is designed to replicate established HPLC methods developed with 3.5 \u2013 5 \u00b5m particle columns onto a state-of-the-art LC platform, while strictly adhering to the guidelines and regulations set forth in USP Chapter 621.<\/p>\n<figure id=\"attachment_1172\" aria-describedby=\"caption-attachment-1172\" style=\"width: 300px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.waters.com\/blog\/wp-content\/uploads\/acquity-arc_multi-flow-path-schematic.jpg\" rel=\"attachment wp-att-1172\"><img decoding=\"async\" class=\"wp-image-1172 size-medium\" src=\"https:\/\/www.waters.com\/blog\/wp-content\/uploads\/acquity-arc_multi-flow-path-schematic-300x134.jpg\" alt=\"The ACQUITY Arc System's multi-flow path helps analysts manage chromatographic conditions.\" width=\"300\" height=\"134\" \/><\/a><figcaption id=\"caption-attachment-1172\" class=\"wp-caption-text\">The ACQUITY Arc System&#8217;s multiple flow path technology helps analysts manage chromatographic dispersion.<\/figcaption><\/figure>\n<p>How is this done? To transfer a method with the ACQUITY Arc System, the analyst chooses one of two flow paths that best replicates the results coming from their legacy HPLC systems. Dwell volume is selectable in the software making it easy to emulate both the dwell volume of the legacy system as well as its mobile phase mixing behavior, and enable the transfer of LC methods from <strong><u>any<\/u><\/strong> commercial LC system.<\/p>\n<p>Then, there are the productivity improvements brought to the analytical laboratory by the ACQUITY Arc System. For example, it\u2019s an accepted fact that LC methods developed by R&amp;D, often on a UPLC instrument, commonly end up as HPLC methods by the time they reach the QC lab. Adjusting UPLC methods developed with smaller sub-2-\u00b5m particle columns to HPLC methods on larger 3.5 \u2013 5 \u00b5m particle columns is one of the tasks the ACQUITY Arc System was intended for. Powered by <a href=\"https:\/\/www.waters.com\/waters\/nav.htm?cid=513188\" target=\"_blank\" rel=\"noopener\">Empower<sup>\u00ae<\/sup> Chromatography Data Software<\/a>, the Arc System is the perfect choice for regulated and QC laboratories.<\/p>\n<p>What\u2019s more, if an analyst wants significantly better throughput and efficiency than they can get from their HPLC method, the system is perfectly suited to convert that method onto a 2.5 \u2013 2.7 \u00b5m particle HPLC column. And by harnessing the power of Waters Auto-Blend Plus\u2122 technology, which enables users to program mobile phase composition directly in units of pH and % organic, minimizing human error often observed with manual mobile phase manipulation.<\/p>\n<p>With true plug-and-play method compatibility for HPLC and UHPLC separations, hundreds of laboratories have adopted the ACQUITY Arc System. Isn\u2019t it time for you to upgrade your HPLC(s) as well?<\/p>\n<p>To learn more, visit <a href=\"https:\/\/www.waters.com\/arc\">www.waters.com\/arc<\/a>.<\/p>\n<p>&nbsp;<\/p>\n<p>Method transfer examples:<\/p>\n<ul>\n<li><a href=\"https:\/\/www.waters.com\/waters\/library.htm?cid=134844390&amp;lid=134856554\" target=\"_blank\" rel=\"noopener\">HPLC Method Transfer for Analysis of Metoclopramide HCl and Related Substances from an Agilent 1100 Series LC System to an ACQUITY Arc System<\/a><\/li>\n<li><a href=\"https:\/\/www.waters.com\/waters\/library.htm?cid=134844390&amp;lid=134875568\" target=\"_blank\" rel=\"noopener\">Method Transfer and Reliability of the ACQUITY Arc for Peptide Mapping<\/a><\/li>\n<li><a href=\"https:\/\/www.waters.com\/waters\/library.htm?cid=134844390&amp;lid=134856832\" target=\"_blank\" rel=\"noopener\">Simplifying Methods Transfer: Novel Tools for Replicating your Established Methods on an ACQUITY Arc System<\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><em>Originally published in Pittcon Today, 3\/7\/2016<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The thought of transferring established high performance liquid chromatography (HPLC) methods onto a another vendor\u2019s LC, or a new platform like UHPLC\/UPLC, may cause a bit of anxiety for those that may be unaware of how easy it can be. The reason that the topic of analytical method transfer induces so much angst is that&#8230;<\/p>\n","protected":false},"author":44,"featured_media":481,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_titles_title":"ACQUITY Arc System: Transferring Validated HPLC Methods | Waters Blog","_seopress_titles_desc":"Method transfer can be anxiety-inducing, but it can be easier than expected, even when switching vendors or platforms. Read more!\r\n","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":"","_seopress_news_disabled":"","_seopress_video_disabled":"","_seopress_video":[],"_seopress_pro_schemas_manual":[],"_seopress_pro_rich_snippets_disable_all":"","_seopress_pro_rich_snippets_disable":[],"_seopress_pro_schemas":[],"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[22],"tags":[137,113,156,170,29,30],"class_list":["post-4431","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technology","tag-acquity-arc","tag-hplc","tag-method-transfer","tag-qc","tag-uhplc","tag-uplc"],"acf":[],"taxonomy_info":{"category":[{"value":22,"label":"Technology"}],"post_tag":[{"value":137,"label":"ACQUITY Arc"},{"value":113,"label":"HPLC"},{"value":156,"label":"method transfer"},{"value":170,"label":"QC"},{"value":29,"label":"UHPLC"},{"value":30,"label":"UPLC"}]},"featured_image_src_large":["https:\/\/www.waters.com\/blog\/wp-content\/uploads\/acquity-arc_multi-flow-path-schematic-1024x458.jpg",1024,458,true],"author_info":{"display_name":"Brian Murphy","author_link":"https:\/\/www.waters.com\/blog\/author\/bmurphy\/"},"comment_info":"","category_info":[{"term_id":22,"name":"Technology","slug":"technology","term_group":0,"term_taxonomy_id":22,"taxonomy":"category","description":"Our expertise drives innovation, development, and\u00a0application of informatics and software that continue to enable leading pharmaceutical, environmental, food &amp; beverage and chemical materials organizations to accelerate decision-making, improve laboratory effectiveness, and get products to market faster.","parent":0,"count":116,"filter":"raw","term_order":"0","cat_ID":22,"category_count":116,"category_description":"Our expertise drives innovation, development, and\u00a0application of informatics and software that continue to enable leading pharmaceutical, environmental, food &amp; beverage and chemical materials organizations to accelerate decision-making, improve laboratory effectiveness, and get products to market faster.","cat_name":"Technology","category_nicename":"technology","category_parent":0}],"tag_info":[{"term_id":137,"name":"ACQUITY Arc","slug":"acquity-arc","term_group":0,"term_taxonomy_id":137,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw","term_order":"0"},{"term_id":113,"name":"HPLC","slug":"hplc","term_group":0,"term_taxonomy_id":113,"taxonomy":"post_tag","description":"","parent":0,"count":17,"filter":"raw","term_order":"0"},{"term_id":156,"name":"method transfer","slug":"method-transfer","term_group":0,"term_taxonomy_id":156,"taxonomy":"post_tag","description":"","parent":0,"count":9,"filter":"raw","term_order":"0"},{"term_id":170,"name":"QC","slug":"qc","term_group":0,"term_taxonomy_id":170,"taxonomy":"post_tag","description":"","parent":0,"count":7,"filter":"raw","term_order":"0"},{"term_id":29,"name":"UHPLC","slug":"uhplc","term_group":0,"term_taxonomy_id":29,"taxonomy":"post_tag","description":"","parent":0,"count":11,"filter":"raw","term_order":"0"},{"term_id":30,"name":"UPLC","slug":"uplc","term_group":0,"term_taxonomy_id":30,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","term_order":"0"}],"_links":{"self":[{"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/posts\/4431","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/users\/44"}],"replies":[{"embeddable":true,"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/comments?post=4431"}],"version-history":[{"count":0,"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/posts\/4431\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/media\/481"}],"wp:attachment":[{"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/media?parent=4431"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/categories?post=4431"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.waters.com\/blog\/wp-json\/wp\/v2\/tags?post=4431"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}