XSelect Peptide Columns

XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pk - 186007038
SKU: 186007038
XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pk - 186007038
List Price
$1030.00
Category: Columns
XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pk - 186007038: Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
Part Number: 186007038
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format XP Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 10000 psi (690 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Columns
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 Method Validation Kit, 130Å, 3.5 µm, 2.1 mm X 100 mm, 3/pk - 176003080
SKU: 176003080
XSelect Peptide CSH C18 Method Validation Kit, 130Å, 3.5 µm, 2.1 mm X 100 mm, 3/pk - 176003080
List Price
$2838.88
Category: Columns
XSelect Peptide CSH C18 Method Validation Kit, 130Å, 3.5 µm, 2.1 mm X 100 mm, 3/pk - 176003080: Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit includes three XSelect CSH130 C18 columns packed with three different batches of sorbent and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003080
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 3 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 2.1 mm X 10 mm, 2/pk - 176003081
SKU: 176003081
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 2.1 mm X 10 mm, 2/pk - 176003081
List Price
$453.14
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 2.1 mm X 10 mm, 2/pk - 176003081: Waters XSelect Peptide CSH C18 130Å 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit includes two XSelect Peptide CSH C18 130Å guard columns and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003081
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Format Column Kit
Inner Diameter 2.1 mm
Length 10 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 2 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 4.6 mm X 100 mm, 1/pk - 176003083
SKU: 176003083
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 4.6 mm X 100 mm, 1/pk - 176003083
List Price
$1037.59
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 4.6 mm X 100 mm, 1/pk - 176003083: Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit includes one XSelect CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003083
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Inner Diameter 4.6 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pk - 176003082
SKU: 176003082
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pk - 176003082
List Price
$853.27
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pk - 176003082: Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit includes one XSelect CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003082
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Inner Diameter 4.6 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pk - 176003069
SKU: 176003069
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pk - 176003069
List Price
$865.00
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pk - 176003069: Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption. This kit includes one XSelect CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003069
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Inner Diameter 2.1 mm
Length 50 mm
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1K - 15K, 1/pk - 186006943
SKU: 186006943
XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1K - 15K, 1/pk - 186006943
List Price
$1030.00
Category: Columns
XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1K - 15K, 1/pk - 186006943: Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
Part Number: 186006943
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format XP Column
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 18000 psi (1240 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Columns
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1K - 15K, 1/pk - 176003093
SKU: 176003093
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1K - 15K, 1/pk - 176003093
List Price
$1030.00
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1K - 15K, 1/pk - 176003093: Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption. This kit includes one XSelect CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003093
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Inner Diameter 4.6 mm
Length 150 mm
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pk - 176003071
SKU: 176003071
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pk - 176003071
List Price
$1030.00
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pk - 176003071: Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption. This kit includes one XSelect CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003071
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Inner Diameter 2.1 mm
Length 150 mm
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 4.6 mm X 100 mm, 1/pk - 176003075
SKU: 176003075
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 4.6 mm X 100 mm, 1/pk - 176003075
List Price
$910.00
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 4.6 mm X 100 mm, 1/pk - 176003075: Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption. This kit includes one XSelect CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003075
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Inner Diameter 4.6 mm
Length 100 mm
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pk - 176003074
SKU: 176003074
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pk - 176003074
List Price
$865.00
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pk - 176003074: Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption. This kit includes one XSelect CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003074
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Inner Diameter 4.6 mm
Length 50 mm
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pk - 176003070
SKU: 176003070
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pk - 176003070
List Price
$910.00
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pk - 176003070: Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption. This kit includes one XSelect CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003070
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Inner Diameter 2.1 mm
Length 100 mm
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 2.1 mm X 50 mm, 1/pk - 176003077
SKU: 176003077
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 2.1 mm X 50 mm, 1/pk - 176003077
List Price
$853.27
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 2.1 mm X 50 mm, 1/pk - 176003077: Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit includes one XSelect CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003077
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Inner Diameter 2.1 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 2.1 mm X 150 mm, 1/pk - 176003079
SKU: 176003079
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 2.1 mm X 150 mm, 1/pk - 176003079
List Price
$1118.39
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 2.1 mm X 150 mm, 1/pk - 176003079: Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit includes one XSelect CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003079
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 100 mm, 3/pk - 176003076
SKU: 176003076
XSelect Peptide CSH C18 Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 100 mm, 3/pk - 176003076
List Price
$2730.00
Category: Columns
XSelect Peptide CSH C18 Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 100 mm, 3/pk - 176003076: Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption. This kit consists of three XSelect CSH130 C18 XP columns packed with three different batches of sorbent and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003076
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
Inner Diameter 4.6 mm
Length 100 mm
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC
USP Classification L1
Units per Package 3 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk - 176003078
SKU: 176003078
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk - 176003078
List Price
$1037.59
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk - 176003078: Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit includes one XSelect CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003078
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pk - 176003073
SKU: 176003073
XSelect Peptide CSH C18 Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pk - 176003073
List Price
$2730.00
Category: Columns
XSelect Peptide CSH C18 Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pk - 176003073: Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption. This kit consists of three XSelect CSH130 C18 XP columns packed with three different batches of sorbent and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003073
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
Inner Diameter 2.1 mm
Length 100 mm
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC
USP Classification L1
Units per Package 3 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk - 176003072
SKU: 176003072
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk - 176003072
List Price
$695.00
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk - 176003072: Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit includes one XSelect CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003072
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Inner Diameter 2.1 mm
Length 5 mm
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC
USP Classification L1
Units per Package 3 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 176003084
SKU: 176003084
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 176003084
List Price
$1113.13
Category: Columns
XSelect Peptide CSH C18 Column Kit, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 176003084: Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit includes one XSelect CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003084
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XSelect Peptide CSH C18 Column, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk - 186006951
SKU: 186006951
XSelect Peptide CSH C18 Column, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk - 186006951
List Price
$900.00
Category: Columns
XSelect Peptide CSH C18 Column, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk - 186006951: Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.
Part Number: 186006951
Brand: XSelect
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Columns
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
Back To Top