XBridge Reversed-Phase OBD Prep Column

XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002977
SKU: 186002977
XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002977
List Price
$1660.00
Category: Columns
XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002977: As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
Part Number: 186002977
Brand: XBridge
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 80 C (Low pH)/60 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 250 mm, 1/pk - 186003900
SKU: 186003900
XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 250 mm, 1/pk - 186003900
List Price
$16600.00
Category: Columns
XBridge BEH C18 OBD Prep Column, 130Å, 10 µm, 50 mm X 250 mm, 1/pk - 186003900: As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
Part Number: 186003900
Brand: XBridge
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 80 C (Low pH)/60 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 100 mm, 1/pk - 186004008
SKU: 186004008
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 100 mm, 1/pk - 186004008
List Price
$2745.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 100 mm, 1/pk - 186004008: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004008
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 250 mm, 1/pk - 186004010
SKU: 186004010
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 250 mm, 1/pk - 186004010
List Price
$3915.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 250 mm, 1/pk - 186004010: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004010
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 50 mm, 1/pk - 186004007
SKU: 186004007
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 50 mm, 1/pk - 186004007
List Price
$1660.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 50 mm, 1/pk - 186004007: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004007
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 150 mm, 1/pk - 186004009
SKU: 186004009
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 150 mm, 1/pk - 186004009
List Price
$3275.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 150 mm, 1/pk - 186004009: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004009
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pk - 186004013
SKU: 186004013
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pk - 186004013
List Price
$7535.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pk - 186004013: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004013
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pk - 186002996
SKU: 186002996
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pk - 186002996
List Price
$3700.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pk - 186002996: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186002996
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pk - 186003083
SKU: 186003083
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pk - 186003083
List Price
$8125.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pk - 186003083: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186003083
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pk - 186004023
SKU: 186004023
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pk - 186004023
List Price
$3915.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pk - 186004023: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004023
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002993
SKU: 186002993
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002993
List Price
$1660.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002993: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186002993
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pk - 186004014
SKU: 186004014
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pk - 186004014
List Price
$9520.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pk - 186004014: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004014
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pk - 186004011
SKU: 186004011
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pk - 186004011
List Price
$8125.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pk - 186004011: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004011
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pk - 186003269
SKU: 186003269
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pk - 186003269
List Price
$4485.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pk - 186003269: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186003269
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 75 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 30 mm X 250 mm, 1/pk - 186004012
SKU: 186004012
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 30 mm X 250 mm, 1/pk - 186004012
List Price
$12250.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 30 mm X 250 mm, 1/pk - 186004012: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004012
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pk - 186002997
SKU: 186002997
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pk - 186002997
List Price
$5425.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pk - 186002997: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186002997
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 250 mm, 1/pk - 186004016
SKU: 186004016
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 250 mm, 1/pk - 186004016
List Price
$16600.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 250 mm, 1/pk - 186004016: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004016
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 150 mm, 1/pk - 186004015
SKU: 186004015
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 150 mm, 1/pk - 186004015
List Price
$13020.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 150 mm, 1/pk - 186004015: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004015
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pk - 186002994
SKU: 186002994
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pk - 186002994
List Price
$2745.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pk - 186002994: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186002994
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pk - 186003938
SKU: 186003938
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pk - 186003938
List Price
$9520.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pk - 186003938: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186003938
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH